beautypg.com

Horner APG XL6 OCS HEXT351C112 User Manual

Page 6

background image

MAN0885-04-EN

Specifications / Installation

__________________________________________________________________________________________________________________________________________________________________

3/2/2010 Page 6 of 6 #1037



7

Derating

















8

I/O Register Map




10

Technical Support


For assistance and manual updates, contact Technical Support at the
following locations:

North America:
Tel: 317 916-4274
Fax: 317 639-4279
Web:

http://www.heapg.com

Email:

[email protected]

Europe:
Tel: +353-21-4321266
Fax: +353-21-4321826
Web:

http://www.horner-apg.com

Email:

[email protected]


9

Safety




























































Registers

Description

%I1 to %I24

Digital Inputs

%I32

Output Fault

%I25 to %I31

Reserved

%Q1 to %Q16

Digital outputs

%Q17

Clear HSC1 accumulator to 0

%Q18

Totalizer: Clear HSC2

Quadrature 1-2: Accumulator 1

Reset to max – 1

%Q19

Clear HSC3 Accumulator to 0

%Q20

Totalizer: Clear HSC4

Quadrature 3-4: Accumulator 3

Reset to max – 1

%Q21 to %Q32

Reserved

%AI1 to %AI4

Analog inputs

%AI5, %AI6

HSC1 Accumulator

%AI7, %AI8

HSC2 Accumulator

%AI9, %AI10

HSC3 Accumulator

%AI11, %AI12

HSC4 Accumulator

%AQ1, %AQ2

PWM1 Duty Cycle

%AQ3, %AQ4

PWM2 Duty Cycle

%AQ5, %AQ6

PWM Prescale

%AQ7, %AQ8

PWM Period

%AQ9 to %AQ14

Analog outputs

Note: Not all XL6 units contain the I/O listed in this table.

Relay Life Expectancy

0

10

20

30

40

1

2

3

4

Contact Current (A)

O

p

e

ra

ti

o

n

(x

1

0

4

)

This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or Non-hazardous
locations only

WARNING
EXPLOSION HAZARD – Do not disconnect equipment unless power has been
switched off or the area is known to be non-hazardous.
AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DECONNECTOR L'EQUIPMENT,
COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON
DANGEREUX.


WARNING:
To avoid the risk of electric shock or burns, always connect the safety (or earth) ground
before making any other connections.

WARNING:
To reduce the risk of fire, electrical shock, or physical injury it is strongly recommended
to fuse the voltage measurement inputs. Be sure to locate fuses as close to
the source as possible.

WARNING:
Replace fuse with the same type and rating to provide protection against risk of fire and
shock hazards.

WARNING:
In the event of repeated failure, do not replace the fuse again as a repeated failure
indicates a defective condition that will not clear by replacing the fuse.

WARNING – EXPLOSION HAZARD
– Substitution of components may impair suitability for Class I,
Division 2.
AVERTISSEMENT - RISQUE D'EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT
RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1,
DIVISION 2.


WARNING
- The USB parts are for operational maintenance only. Do not leave permanently
connected unless area is known to be non-hazardous.


WARNING
EXPLOSION HAZARD - BATTERIES MUST ONLY BE CHANGED IN AN AREA
KNOWN TO BE NON-HAZARDOUS
AVERTISSEMENT - RISQUE D'EXPLOSION - AFIN D'EVITER TOUT RISQUE D'EXPLOSION,
S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX AVANT DE CHANGER
LA BATTERIE.


WARNING
- Battery May Explode If Mistreated. Do Not Recharge, Disassemble or Dispose Of In
Fire.

WARNING:
Only qualified electrical personnel familiar with the construction and operation of this
equipment and the hazards involved should install, adjust, operate, or service this equipment. Read
and understand this manual and other applicable manuals in their entirety before proceeding.
Failure to observe this precaution could result in severe bodily injury or loss of life.

All applicable codes and standards need to be followed in the installation of this product.
Adhere to the following safety precautions whenever any type of connection is made to the module:

Connect the safety (earth) ground on the power connector first before making any other

connections.

When connecting to electric circuits or pulse-initiating equipment, open their related breakers.
Do not make connections to live power lines.
Make connections to the module first; then connect to the circuit to be monitored.
Route power wires in a safe manner in accordance with good practice and local codes.
Wear proper personal protective equipment including safety glasses and insulated gloves when

making connections to power circuits.

Ensure hands, shoes, and floors are dry before making any connection to a power line.
Make sure the unit is turned OFF before making connection to terminals.
Make sure all circuits are de-energized before making connections.
Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately if

defective.

Use Copper Conductors in Field Wiring Only, 60/75° C

This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:

1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause

undesired operation.

Radiated Emission Compliance: For compliance requirement, a ferrite (Horner P/N FBD006
supplied with the unit) needs to be placed on the AC/DC line with one loop.

"WARNING: EXPOSURE TO SOME CHEMICALS MAY DEGRADE

THE SEALING PROPERTIES OF MATERIALS USED IN THE Tyco relay

PCJ

Cover / case & base: Mitsubishi engineering Plastics Corp.

5010GN6-30 or 5010GN6-30 M8 (PBT)

Sealing Material: Kishimoto 4616-50K (I part epoxy resin)

It is recommended to periodically inspect the relay for any

degradation of properties and replace if degradation is found

Warning: Consult
user documentation.

Warning: Electrical
Shock Hazard.

When found on the product, the following symbols specify:

No part of this publication may be reproduced without the prior agreement and written permission of
Horner APG, Inc. Information in this document is subject to change without notice.