Figure 4-3. numerical printout – MagTek InSpec 9000 User Manual
Page 43
Section 4. Graphics Presentations
33
InSpec 9000 numerical test results
Description:
Date and Time Printed: 1/29/98 10:41:18 AM
Track No.:
1
2
3
Min
Avg
Max
Min
Avg
Max
Min
Avg
Max
Amplitude%: 125 135
141
105 111 117
109 113 117
Bit Size%:
-11.7 -0.4 12.7
-10.0 -0.6 11.6
-10.9 -0.3 13.5
Sub
Interval%:
3.2 3.0 1.1
-3.3 -0.7 2.0
4.2 -0.4 2.7
Adj. Bit Size%:
-11.8 0.0 14.0
-11.0 0.0 12.0
-11.6 0.0 12.7
Adj. Sub Bit Size%:-3.8
0.0
3.9
-3.0 0.0 2.7
-4.8 0.0 3.9
Start Sentinel (in):
0.301 in
0.303
in
0.301
in
Start Sentinel (mm)
7.652 mm
7.702 mm
7.645 mm
Green - Within ISO Limits for New Card.
Yellow - Within ISO Limits for Returned Card.
Red - Exceeds All ISO Limits
Limits
Track No.:
1
2
3
Red
Green Red Red
Green Red Red
Green
Red
Yellow Yellow Yellow
Yellow Yellow Yellow
Amplitude%:
52 64 126 136
52 64 126 136
52
64 126 136
Bit Size%:
-15 -10 10 15
-15 -7
7 15 -15 -10 10 15
Sub Interval%:
-20 -12 12
20
-20 -10 10 20 20 -12 12 20
Adj. Bit Size%: -15 -10 10 15
-15 -10 10 15
-15 -10 10 15
Adj. Sub Bit Size%: -30 -12 12 30
-30 -12 12 30
-30 -12 12 30
Start Sentinel (in): 0.123 0.273 0.313 0.493 0.223 0.273 0.313 0.493 0.123 0.253 0.333 0.493
Start Sentinel (mm): 3.12 6.93 7.95 0.693 5.66 6.93 7.95 12.52
3.12 6.43 8.46 12.52
Measurement uncertainty of the InSpec 9000 System: Average amplitude +/-15%; Average bit size +/-2%; Start Sentinel +/-.007 inches.
To maintain the range of measurement uncertainty, the tester and card must be clean.
The card must also be flat and within ISO size specifications.
This product tests Amplitude, Jitter, Start Sentinel, and Baseline Integrity. There are other parameters that may influence read
reliability.
Before testing for limits, the program removes 0.130 inch from each end of the data.
Figure 4-3. Numerical Printout