Red Lion PAXLCR User Manual
Page 11

11
will restore the output to the same state it was at before the meter was
powered down.
will activate the output at power up.
will deactivate the
output at power up.
SETPOINT OUTPUT POWER-UP STATE
Normal (
) turns the output “on” when activated and “off” when
deactivated. Reverse (
) turns the output “off” when activated and “on”
when deactivated.
SETPOINT OUTPUT LOGIC
SETPOINT VALUE
Enter the desired Setpoint value. To enter a negative setpoint value,
increment digit 6 to display a “-” sign (Counter A only).
This parameter automatically resets the Setpoint Assigned Counter (A or B)
each time the Setpoint value is reached. The automatic reset can occur at output
start, or output end if the Setpoint Output Action is programmed for timed
output mode. The Reset-to-Count Load selections (“
”) only apply to
Counter A assignment. This reset may be different from the Counter A Reset
Action selected in Module 1.
COUNTER AUTO RESET
Selecting
causes the Setpoint output to deactivate (reset) when the
Setpoint Assigned Counter is reset. The counter reset can occur by the RST
button, User Input or Counter Reset at Power-up.
This output reset will not occur when the Assigned Counter is reset by a
Setpoint generated Counter Auto Reset.
SETPOINT OUTPUT RESET WITH MANUAL RESET
Count B:
to
Count A:
to
Rate:
to
This parameter will deactivate Setpoint 1 output at the Start or End of
Setpoint 2 output (O1 off at O2). The “
” setting only applies if Setpoint 2
Output Action is programmed for timed output.
SETPOINT 1 OUTPUT OFF AT SETPOINT 2 (SP1 Only)
This parameter will deactivate Setpoint 2 output at the Start or End of
Setpoint 1 output (O2 off at O1). The “
” setting only applies if Setpoint 1
Output Action is programmed for timed output.
SETPOINT 2 OUTPUT OFF AT SETPOINT 1 (SP2 Only)
High Acting Boundary Type activates the output when the assigned display
value (
) equals or exceeds the Setpoint value. Low Acting activates the
output when the assigned display value is less than or equal to the Setpoint.
SETPOINT BOUNDARY TYPE
This parameter only applies to Low Acting Boundary Type setpoints. Select
to disable a Low Acting Setpoint at power-up, until the assigned display
value crosses into the output “off” area. Once in the output “off” area, the
Setpoint will then function per the description for Low Acting Boundary Type.
SETPOINT STANDBY OPERATION
Normal (
) displays the setpoint annunciator when the corresponding output
is “on”. Reverse (
) displays the setpoint annunciator when the output is “off”.
SETPOINT ANNUNCIATOR
This parameter selects the action of the Setpoint output as described in the
chart below. Boundary mode is not applicable for Counter B assignment.
SETPOINT OUTPUT ACTION
When Count
> Setpoint
When Count
< Setpoint
When Count
Setpoint
When Count
Setpoint
Boundary Mode
(Low Acting)
Boundary Mode
(High Acting)
After Setpoint
Output Time-Out
When Count =
Setpoint
Timed Output Mode
At Manual Reset
(if
=
)
When Count =
Setpoint
Latched Output Mode
OUTPUT DEACTIVATES
OUTPUT ACTIVATES
DESCRIPTION
SPT ACTION
SETPOINT OUTPUT TIME-OUT
This parameter is only active if the Setpoint Action is set to timed output
mode (
). Enter the value in seconds that the output will be active, once
the Setpoint Value is reached.
to
seconds
SELECTION
ACTION
No Auto Reset
Reset to Zero at the Start of output activation
Reset to Count Load value at the Start of output activation
Reset to Zero at the End of output activation (timed out only)
Reset to Count Load at the End of output activation (timed out only)