GENERAL DESCRIPTION

The PAXLCR is a versatile meter that provides a single or dual counter with

rate indication, scaling and dual relay outputs. The 6-digit display has 0.56" high
digits with adjustable display intensity. The display can be toggled manually or
automatically between the selected counter and rate values.

The meter has two signal inputs and a choice of eight different count modes.

These include bi-directional, quadrature and anti-coincidence counting, as well
as a dual counter mode. When programmed as a Dual Counter, each counter has
separate scaling and decimal point selection.

Rate indication is available in all count modes. The Rate Indicator has

separate scaling and decimal point selection, along with programmable display
update times. In addition to the signal inputs, the User Input can be programmed
to perform a variety of meter control functions.

Two setpoint outputs are provided, each with a Form C relay. The outputs can

activate based on either counter or rate setpoint values. An internal batch counter
can be used to count setpoint output activations.

The PAXLCR can be powered from a wide range of AC or DC voltages. The

meter has been specifically designed for harsh industrial environments. With a
NEMA 4X/IP65 sealed bezel and extensive testing to meet CE requirements, the
meter provides a tough yet reliable application solution.

MODEL NO.

DESCRIPTION

PART NUMBER

PAXLCR

Dual Counter & Rate Meter with Dual Relay Output

PAXLCR00

PAXLCRU

UL Listed Dual Counter & Rate Meter with Dual
Relay Output

PAXLCRU0

SAFETY SUMMARY

All safety regulations, local codes and instructions that appear in this and

corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected to
it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired. Do not use this meter
to directly command motors, valves, or other actuators not equipped with
safeguards. To do so can be potentially harmful to persons or equipment in the
event of a fault to the meter

SPECIFICATIONS

1. DISPLAY: 6 digit, 0.56" (14.2 mm) intensity adjustable Red LED

2. POWER REQUIREMENTS:

AC POWER: 50 to 250 VAC 50/60 Hz, 12 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs
DC POWER: 21.6 to 250 VDC, 6 W
DC Out: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/VDC

+24 VDC @ 50 mA if input voltage is less than 50 VDC

3. COUNTER DISPLAYS:

Counter A: 6-digits, enabled in all count modes

Display Designator: “A” to the left side of the display
Display Range: -99999 to 999999

Counter B: 6-digits, enabled in Dual Count mode or Batch Counter

Display Designator: “B” to the left side of the display
Display Range: 0 to 999999 (positive count only)

Overflow Indication: Display “” alternates with overflowed count value
Maximum Count Rates: 50% duty cycle, count mode dependent.

With setpoints disabled: 25 KHz, all modes except Quadrature x4 (23 KHz).
With setpoint(s) enabled: 20 KHz, all modes except Dual Counter (14 KHz),

Quadrature x2 (13 KHz) and Quadrature x4 (12 KHz).

6 DIGIT, 0.56" HIGH RED LED DISPLAY

PROGRAMMABLE SCALING FOR COUNT AND RATE

BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL

QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION)

BUILT-IN BATCH COUNTING CAPABILITY

PROGRAMMABLE USER INPUT

DUAL 5 AMP FORM C RELAYS

UNIVERSALLY POWERED

NEMA 4X/IP65 SEALED FRONT BEZEL

MODEL PAXLCR - PAX LITE DUAL COUNTER AND RATE METER

DIMENSIONS In inches (mm)

Bulletin No. PAXLCR- B
Drawing No. LP0749
Released 04/09

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: Risk of electric shock.

ORDERING INFORMATION

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is

2.1" (53.4) H x 5.0" (127) W.

CC

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

51EB

For Model No. PAXLCRU0 Only