Red Lion LEGEND User Manual
Page 24
PROGRAM DISPLAY MODULE
Each of the indication displays are programmed individually. Each line of
each indication display can be programmed to show mnemonics (MNE), a
numeric value (VAL), output status, a preset value, or the counter load value. If a
display shows the mnemonic and numeric value of the same parameter, each on a
separate line of the same display the full mnemonic will be displayed as follows:
RATE
PEAK
VALLEY
COUNT
If an indication display is to show two different numeric values, one for each
line, then there will be a single or dual character mnemonic to the left of the
numeric value. This will also be the same if one line is programmed for output
status, preset value, or counter load value and the other a numeric value.
DISPLAYS 1 - 4
Each line of each display has the same programmable options. MNE is the
abbreviation for Mnemonics and VAL is for value.
The following is a list of the single or dual character mnemonics that will
be displayed:
R
Indicates the Rate Value.
Rp
Indicates the Rate Peak Value.
Rv
Indicates the Rate Valley Value.
C
Indicates the Counter Value.
O-
n n
Indicates output status:
The block (
n
) to the left will change to the digit 1 when
output 1 is active.
The block (
n
) to the right will change to the digit 2 when
output 2 is active.
P1
Indicates Preset 1 Value.
P2
Indicates Preset 2 Value.
CL
Indicates Counter Load Value.
SCROLL SPEED (SCRO.SPD)
The indication displays can be set to scroll automatically at a 2.5 or 5
second scroll rate. The displays can be selected not to scroll, in which case the
up and down arrow keys are used to scroll through the displays.
The following flowchart shows only the Display portion: