beautypg.com

Outback Power Systems VFX Series International Programming Manual User Manual

Page 12

background image

11

ADV/FX/INVERTER-------P00

search

60

cycles
pulse spacing

DOWN INC DEC PORT

ADV/FX/INVERTER-------P00

low battery 10.5 vdc
cut-out set point

DOWN INC DEC PORT

ADV/FX/INVERTER-------P00

low battery 12.5 vdc
cut-in set point

DOWN INC DEC PORT

ADV/FX/INVERTER-------P00

adjust 230 vac
output voltage

DOWN INC DEC PORT

The search pulse spacing screen adjusts the

amount of time the FX waits before producing

additional AC pulses to sense a load. The higher

the number of cycles, the lower the FX power

consumption, but the longer it takes before AC

loads are powered. The cycles range from 4 to

120 cycles (two seconds). Press to view

the low battery cut-out screen.

low battery cut-out establishes when the FX turns

off to avoid draining the battery. If an AC source

is available and AC INPUT is set to DROP, the FX

will transfer the AC loads on the FX to the AC

source. A built-in fi ve-minute delay reduces

nuisance FX shutdowns. This setting’s range is

between 9.0VDC and 12.0VDC. Press

to view the next INVERTER screen.

The low battery cut-in set point determines when

the FX will turn on after shutting off due to a low

battery voltage. A 10-minute fi xed delay reduces

on and off system cycling. This setting’s range is

between 10.0VDC and 14.0VDC. Press

to view the adjust output voltage screen.

A user can adjust the inverter function’s output

voltage using this screen. Adjustments might be

necessary if some loads are far away from the FX

or if some are sensitive to higher voltages. This

setting’s range is between 220VAC and 250VAC.

Press

to view the next INVERTER screen.

DOWN

DOWN

DOWN

DOWN