PowerTap SLC+ User Guide User Manual
Page 38
-Slide the battery pack back into position along the center core. As the pack is engaged a
small increase of resistance to installation should be felt as the electrical connections are
made.
- Thread the cap all the way back on.
- Replacement O-rings and battery packs are available from Saris Cycling Group.
TEST MODE
1) From the computer setup main menu press [SELECT] and scroll until the letter “t” is flash-
ing. Press [MODE] to enter test mode setup.
2) Press [MODE] to scroll through the different test modes as shown by the number. NOTE:
Press and hold [MODE] and [SELECT] simultaneously returns to standard operation.
0 - Model and version.
Displays the computer model on the middle line and firmware version number on the bot-
tom line.
1 - LCD Test
Displays all the LCD segments. Press [SELECT] to return to the normal screen.
2 - Heart Rate Signal Test
NOTE: The heart rate signal is illuminated.
The middle line display flashes “88” with each heart rate blip received.
3- Torque Information
NOTE: The T icon is displayed.
This displays information about the internal workings of the torque readings. The bottom dis-
play is the offset torque value directly sent by the hub torque with no correction applied. The
hub sends a value of approximately 512 as the zero point. The middle line display is the cor-
rection offset value currently stored in the computer. This is the value that is changed when
you do a manual zeroing of the torque. The top display is the corrected actual torque (the
bottom value minus the middle value).
38