beautypg.com

PowerTap SLC+ User Guide User Manual

Page 36

background image

COMPUTER BATTERIES
The PowerTap SL2.4 has batteries in the hub and computer. Computer bat-
teries typically need to be changed every 400 hours of use. The computer
will also say “low bat” when the computer battery needs to be changed.
This message is displayed after a “clr” is performed. To replace computer
battery (Type CR2032), remove the computer from the mount. Remove the
battery cover on the back of the computer (use a cone wrench to remove
the battery cover), exchange the battery, and replace the cover as shown
below (FIGURE 29).

TECHNICAL SPECIFICATIONS
Accuracy

+/-1.5%

Signal Transmission

2.4 Ghz

Interval Data Storage

Unlimited

Interval Display

9 Intervals (internal recording)

Operational Temperature

0 to 40 degrees c or 32 to 104 f

Battery Life (Hub)

300 hours approx.

Battery Life (CPU)

400 hours approx.

Battery Type (Hub)

Type 357/303 or EPX 76 (2 ea) - (IEC-SR44)

Battery Type (CPU

CR2032

RANGE OF MEASUREMENT
Power

0-1999 Watts

Torque

0-1999 inch-lbs.

Speed

2-59 mph (3-95 KPH)

Distance

0.00 to 9999.99 (Miles)

Trip Time

0.00.00-999.99 Minutes

Cadence

40-240 RPM

Total energy

0-99999 Kilojoules

Odometer

0-99999 Miles or Kilometers

Heart Rate

0-255 BPM (Beats per Minute)