HP Insight Management Agents User Manual
Page 68
•
Controller Status displays the status of the controller hardware. The following values are valid:
OK - The controller is operating normally.
◦
◦
Failed - The controller has failed and is no longer operating.
◦
Offline - The controller is offline.
◦
Redundant Path Offline - There are multiple connection paths to this controller. At least
one connection path is available and at least one connection path is not available.
◦
Unknown - Indicates that the Storage Agents are unable to determine the status of the
controller. You may need to upgrade the Storage Agents.
•
Current Role displays the array controller's current role for duplexed array controllers. The
following values are valid:
◦
Not Duplexed - This array controller is not duplexed.
◦
Active - This duplexed array controller is the active controller.
◦
Backup - This duplexed array controller is the backup controller.
◦
Unknown - Indicates that the Storage Agents are unable to determine the role of the
controller. You may need to upgrade the Storage Agents.
•
Redundancy Type displays the type of redundant configuration. The following values are valid:
Not Redundant - This array controller is not in a redundant configuration.
◦
◦
Firmware Active/Standby - The array controller is using an active/standby algorithm
implemented in the controller firmware and the operating system driver.
◦
Firmware Primary/Secondary - The array controller is using a primary/secondary algorithm
implemented in the controller firmware and the operating system driver.
◦
Unknown - Indicates that the Storage Agents are unable to determine the type of
redundancy for the controller. You may need to upgrade the Storage Agents.
•
Redundancy Error displays the redundancy error for the controller. The following values are
valid:
◦
No Failure - No failures have been detected.
◦
No Redundant Controller - No redundant controller is installed.
◦
Different Hardware - The other controller indicates a different hardware model.
◦
No Link - A link to the other controller could not be established.
◦
Different Firmware - The other controller indicates a different firmware version.
◦
Different Cache - The other controller indicates a different cache size.
◦
Other Cache Failure - The other controller indicates a cache failure.
◦
No Drives - This controller cannot see any attached drives, but the other controller can.
◦
Other No Drives - This controller can see the attached drives, but the other controller
cannot.
◦
Unsupported Drives - One or more attached drives has been determined to be incapable
of properly supporting redundant controller operation.
◦
Expand in Progress - An expand operation is in progress. Redundant operation not
supported until the expand operation is complete.
◦
Unknown - Indicates that the Storage Agents are unable to determine the redundancy
error for the controller. You may need to upgrade the Storage Agents.
68
Agent information