Array controller information – HP Insight Management Agents User Manual
Page 67
◦
Fans - This is a composite of all the installed fan modules.
◦
Unknown - The Storage Agents are unable to determine the location of this storage system
fan module.
•
Status displays the status of the fan module. The following values are possible:
OK - The fan module is installed and operating normally.
◦
◦
Degraded - The fan module degraded.
◦
Failed - The fan module is failed. Replace the fan module.
◦
Not Installed - The fan module is not installed.
◦
Unknown - The Storage Agent is unable to determine if this storage system fan module is
installed.
•
Serial Number displays the serial number for the fan module. Use this information for
identification purposes.
•
Board Revision displays the board revision of the fan module.
Array Controller Information
This section displays the following information about array controllers that are installed in a storage
system.
•
Model displays the model name of the controller card.
•
Firmware Version displays the version of the controller's firmware.
•
Serial Number displays the serial number of the controller. Use this information for identification
purposes.
•
Product Revision displays the product revision of the controller. Use this value to further identify
a particular revision of the controller model.
•
World Wide Port Name displays the unique Fibre Channel port name for the controller. Use
this value to further identify a particular controller.
•
World Wide Node Name displays the unique Fibre Channel node name for the controller.
Use this value to further identify a particular controller.
•
Rebuild Priority displays the logical drive rebuild priority of the controller. The following values
are valid:
◦
Low - indicates the rebuild priority is low.
◦
Medium - indicates the rebuild priority is medium.
◦
High - indicates the rebuild priority is high.
◦
Unknown - indicates that the rebuild priority is not recognized. You may need to upgrade
the Storage Agents.
•
Expand Priority displays the logical drive expand priority of the controller. The following values
are valid:
◦
Low - indicates the expand priority is low.
◦
Medium - indicates the expand priority is medium.
◦
High - indicates the expand priority is high.
◦
Unknown - indicates that the expand priority is not recognized. You may need to upgrade
the Storage Agents.
Storage agent
67