HP Insight Management Agents User Manual
Page 64
•
Fan Status displays the current status of the fans in the storage system backplane. The following
values are possible:
◦
OK - The fans are installed and operating normally.
◦
Degraded - At least one fan has failed, but there is still sufficient cooling capacity to allow
the storage system to continue. The failed fan should be replaced.
◦
Degraded (Fan 1 Failed) - The fan in bay 1 has failed, but there is still sufficient cooling
capacity to allow the storage system to continue. The failed fan should be replaced.
◦
Degraded (Fan 2 Failed) - The fan in bay 2 has failed, but there is still sufficient cooling
capacity to allow the storage system to continue. The failed fan should be replaced.
◦
Failed - One or more fans have failed and there is insufficient cooling capacity to protect
the storage system from damage. The failed fans should be replaced.
◦
Not Installed - This storage system backplane does not have a fan installed.
◦
Not Supported - This storage system does not support reporting fan status through this
storage system backplane. The fan status is reported through the first backplane on this
storage system.
◦
Unknown - The Storage Agent is unable to determine the fan status.
•
Speed displays the speed of the storage system backplane. The following values are possible:
Ultra3 - The storage system is capable of Ultra3 speeds.
◦
◦
Ultra320 - The storage system is capable of Ultra320 speeds.
◦
SATA - The storage system is capable of SATA speeds.
◦
Unknown - The Storage Agents are unable to determine the storage system backplane
speed. You may need to upgrade your software.
•
Drive Bays displays the number of bays on this storage system backplane.
•
Temperature Status displays the current temperature status of the storage system backplane.
The following values are possible:
◦
OK - The temperature is within the normal operating range.
◦
Degraded - The temperature is outside of the normal operating range.
◦
Failed - The temperature has exceeded the safe operating temperature and could
permanently damage the storage system.
◦
Not Monitored - This storage system does not support temperature monitoring.
◦
Not Supported - This storage system does not support reporting the temperature status
through this storage system backplane. The temperature status is reported through the
first backplane on this storage system.
◦
Unknown - The Storage Agent is unable to determine the temperature status.
•
Placement indicates the location of the storage system backplane. The following values are
valid:
◦
Internal - The storage system backplane is located inside the external array storage system
chassis.
◦
External - The storage system backplane is located outside the external array storage
system chassis in an external storage system.
◦
Unknown - The Storage Agent could not determine the location of the storage system
backplane.
64
Agent information