HP Insight Management Agents User Manual
Page 60
•
Thermal Status—Displays the temperature status of the drive system. The following values are
possible:
◦
OK—The temperature is within normal operating range.
◦
Degraded—The temperature is outside of normal operating range. Check to make sure
the cover is on the storage system.
◦
Failed—The temperature is outside of normal operating range, and could permanently
damage the system. Ensure that the fans are spinning, and check the room temperature.
◦
Unknown—The Storage Agents do not recognize the thermal status. You may need to
upgrade your software.
◦
No Temperature Monitoring—This storage system does not support temperature monitoring.
•
Side Panel—Displays the status of the side panel of the drive enclosure, or box. The following
values are possible:
◦
In Place—The side panel is closed.
◦
Removed—The side panel is not in place or not completely closed.
◦
Unknown—The Storage Agents do not recognize the side panel status. You may need
to upgrade your software.
◦
No Panel Detection—This storage system does not support side panel detection.
•
Duplex Option—Displays the duplex option installed in this storage system. The following
values are possible:
◦
Duplex Top—This storage system is the top part of a duplexed unit.
◦
Duplex Bottom—This storage system is the bottom part of a duplexed unit.
◦
None—A duplex option is not installed.
•
Power Supply Status—Displays the status of the redundant power supply. The following values
are possible:
◦
OK—All component power supplies that make up the redundant power supply are in
normal working order.
◦
Degraded—One of the component power supplies that make up the redundant power
supply has failed. The drive system (either a drive subsystem or a power supply for the
main unit) continues to operate; however, if the remaining power supply should fail, the
drive system loses power and data loss could occur. To correct this situation, schedule a
time to bring the device down and replace the failed power supply.
60
Agent information