beautypg.com

Sata or sas ids – HP ProLiant DL580 G3 Server User Manual

Page 29

background image

Server component identification

29

Activity
LED (1)

Online
LED (2)

Fault LED
(3)

Interpretation

Flashing Flashing Flashing Do not remove the drive. Removing a drive may cause data

loss in non-fault-tolerant configurations.

Either (1) the drive is part of an array being selected by an array
configuration utility; (2) Drive Identification has been selected in
HP SIM; or (3) drive firmware is being updated.

Off

Off

On

The drive has failed and has been placed offline.

You may replace the drive.

Off

Off

Off

Either (1) the drive is not configured as part of an array; (2) the
drive is configured as part of an array, but it is a replacement drive
that is not being accessed or being rebuilt yet; or (3) the drive is
configured as an online spare.

If the drive is connected to an array controller, you may replace the
drive online.

SATA or SAS IDs

NOTE: The server may look different from that shown.

When adding SAS hard drives to the server, observe the following general
guidelines: