POST error messages and beep codes
List of messages:
Introduction to POST error messages
The error messages and codes in this section include all new messages generated
by this server. Some messages are informational and do not indicate an error. A
server generates only the codes that are applicable to its configuration and
options.
For a complete listing of error messages, refer to the POST error messages in the
HP ProLiant Servers Troubleshooting Guide located on the Documentation CD
or on the HP website (
WARNING: To avoid potential problems, ALWAYS read the
warnings and cautionary information in the server documentation
before removing, replacing, reseating, or modifying system
components.
209-Hot-add Memory Configuration - Boards must be installed sequentially
Action: Install or reinstall DIMMs to support hot-add memory configuration.
209-Mirror Memory Configuration - DIMMs on Both Boards do not Match
Audible Beeps: 1 long, 1 short
Possible Cause: Memory boards are not populated identically, or a memory
board is missing.
Action: Be sure four memory boards are installed and DIMMs are populated
correctly.