Preparing the server for diagnosis – HP ProLiant DL580 G3 Server User Manual
Page 147
Troubleshooting
147
•
Do not disable the power cord grounding plug. The grounding
plug is an important safety feature.
•
Plug the power cord into a grounded (earthed) electrical outlet
that is easily accessible at all times.
•
Unplug the power cord from the power supply to disconnect
power to the equipment.
•
Do not route the power cord where it can be walked on or
pinched by items placed against it. Pay particular attention to
the plug, electrical outlet, and the point where the cord extends
from the server.
63.5 kg
140 lb
WARNING: To reduce the risk of personal injury or damage to the
equipment:
•
Observe local occupation health and safety requirements and
guidelines for manual handling.
•
Obtain adequate assistance to lift and stabilize the chassis
during installation or removal.
•
The server is unstable when not fastened to the rails.
•
When mounting the server in a rack, remove the power
supplies and any other removable module to reduce the overall
weight of the product.
CAUTION: To properly ventilate the system, you must provide at
least 7.6 cm (3.0 in) of clearance at the front and back of the server.
CAUTION: The server is designed to be electrically grounded
(earthed). To ensure proper operation, plug the AC power cord into a
properly grounded AC outlet only.
Preparing the server for diagnosis
1.
Be sure the server is in the proper operating environment with adequate
power, air conditioning, and humidity control. Refer to the server
documentation for required environmental conditions.