Grounding methods to prevent electrostatic
discharge

Several methods are used for grounding. Use one or more of the following
methods when handling or installing electrostatic-sensitive parts:

Use a wrist strap connected by a ground cord to a grounded workstation or

computer chassis. Wrist straps are flexible straps with a minimum of
1 megohm

±

10 percent resistance in the ground cords. To provide proper

ground, wear the strap snug against the skin.

Use heel straps, toe straps, or boot straps at standing workstations. Wear the

straps on both feet when standing on conductive floors or dissipating floor
mats.

Use conductive field service tools.

Use a portable field service kit with a folding static-dissipating work mat.

If you do not have any of the suggested equipment for proper grounding, have an
authorized reseller install the part.