beautypg.com

Figure 50, Sample hardware event notification 99 – HP StorageWorks 2300 Disk System User Manual

Page 99

background image

Troubleshooting

99

T

roub
le

shoo

ting

Figure 50.

Sample Hardware Event Notification

Notification Time: Wed Feb 3 11:27:15 1999

yourserver sent Event Monitor notification information:

/storage/events/enclosures/ses_enclosure/8_0_1_0.15.0 is >=1.

Its current value is MAJORWARNING(3)

Event data from monitor:

Event Time: Wed Feb 3 11:27:15 1999

Hostname: yourserver.rose.hp.com IP Address : 15.43.213.13

Event ID: 0x0036b8a313000000002 Monitor : dm_ses_enclosure

Event # : 402 Event Class: I/O

Severity : MAJOR WARNING

Enclosure at hardware path 8/0/1/0.15.0: Hardware failure

Associated OS error log entry id(s): None

Description of Error:

The enclosure services controllers have different versions of

firmware.

Probable Cause / Recommended Action:

The enclosure services controller cards have different versions

of firmware. Update the controllers to the same version of

firmware.

User Defined Annotation: Enclosure 37 BCC A.