Isolating faults, Isolating faults 104, Table 12 – HP StorageWorks 2300 Disk System User Manual

Page 104: Troubleshooting table 104

background image

104

Troubleshooting

Isolating Faults

Table 12 lists the probable causes and solutions for problems you may detect on
the disk system. When more than one problem applies to your situation,
investigate the first description that applies. The table lists the most basic
problems first and excludes them from subsequent problem descriptions.

Table 12.

Troubleshooting Table

Problem

Description

HW Event

Category

LED

State

STM

Status

Probable Cause/Solution

Installed
product does
not power on

none

System
power
LED off

none

Neither power cord is plugged in.

The power switch is not pressed.

AC breaker is tripped.

AC power source has failed.

The PDU/PDRU is defective.

Power switch is defective.

A faulty component is causing
power supplies to turn off. Remove
all components and reinsert one at
a time until the faulty component is
isolated.

System fault
LED is on

none

Power
supply
LED off

Power
supply Not
Available

One power supply is not functional.

The PDU/PDRU or primary power
source has failed.

Critical

Part fault
LED on

Critical

A component has failed. See
problem descriptions below.

Audio alarm
when BCC
installed

none

BCC Fault
flashing

Disk Not
Available

BCC DIP switch settings do not
match peer BCC switch settings.
Reset switches.

Improper cable/terminator connections

BCC Fault
LED is on

Critical

BCC Fault
on

Critical

BCC hardware is faulty.
Replace the BCC.