beautypg.com

Ac power input, Dc power output, Heat output – HP StorageWorks 2300 Disk System User Manual

Page 146: Environment, Ac power input 146, Dc power output 146, Heat output 146, Environment 146

background image

146

Reference

AC Power Input

The disk system operates at 100-127 and 200-240 V AC, 50-60 Hz, single phase,
power factor corrected. Maximum current is 4.8 amps over the low voltage range
and 2.0 amps over the high voltage range. Average power consumption with
medium load (14 disks running idle) is 345 watts.

DC Power Output

Disk: +5 V and +12 V from power supply

BCC: +5 V and +3.3 V from power supply

Heat Output

1600 BTU/hr.

Environment

The following environmental specifications were type-tested under controlled
conditions. Hewlett-Packard maintains an active program of auditing production
products to make sure these specifications remain true when products are retested
under the same conditions. However, the limits of these specifications do not
represent the optimum for long, trouble-free operation and specifically are not
recommended for maximum satisfaction. The recommended conditions are
stated when appropriate.

Operating temperature: 5º C to 38º C (41º F to 100º F)
Recommended: 20º C to 25.5º C (68º F to 78º F)

Storage temperature: -40º C to 70º C (-40º F to 158º F)

Maximum gradient: 20º C per hour (36º F per hour)

Relative humidity:10% to 80% noncondensing, max. wetbulb at 28º C
Recommended:30% to 50% noncondensing

Altitude:3000 m (10,000 ft.)

Note

For continuous, trouble-free operation, the disk system should
NOT be operated at its maximum environmental limits for
extended periods of time. Operating within the recommended
operating range, a less stressful operating environment, ensures
maximum reliability.