HP XP P9500 Storage User Manual
Page 83

•
Forward Path Watch Time—establishes whether to forward the Path Watch Time value of the
master journal to the restore journal.
•
Transfer Speed—which specifies the speed for data transfer
•
Delta Resync Failure—which specifies the processing that takes place in the event of a failure.
Prerequisite information
Please be aware of the following when changing mirror options:
•
Mirror options can be changed on both primary and secondary systems.
•
To change mirror options, the status of the mirror must be one of the following:
Initial
◦
◦
Active
◦
Stopped
◦
Hold
◦
Holding
◦
Hold(Failure)
•
The Transfer Speed option can be changed if the mirror’s status is Active, Hold, or Holding.
•
When changing options for multiple mirrors, you can leave some options unchanged by
entering or selecting no value. If you specify a value, it is applied to the selected mirrors.
Procedure 20 To change options for a mirror
1.
In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal > Journal Operation. The Journal Operation window displays.
2.
Click
to change the mode from View to Modify.
3.
In the table pane, right-click the desired journal and then select Mirror > Change Mirror Option.
4.
For Unit of Path Watch Time, specify the unit of time for Path Watch Time, minute, hour, or
day.
Journal and mirror maintenance
83