Raid manager error codes for cnt ac-j: ssb1 = b9e1 – HP XP P9500 Storage User Manual
Page 112
Description
Error code (SSB2)
The pair cannot be created because cache CL2 is in abnormal status.
8F46
The pair cannot be created because cache CL1 is in abnormal status.
8F47
The pair cannot be created or resynchronized due to the following contributing factors:
8F4D
•
A journal is not registered in the secondary storage system.
•
A volume in the journal which is registered in the secondary storage system is blocked.
The pair cannot be created or resynchronized because the load of the processing was high. Wait
about 5 minutes, then retry the operation.
8F50
The pair cannot be created because the status of the configuration could not be transited.
8F53
The pair cannot be created or resynchronized because of the one of following reasons.
8F58
•
The pair status of the specified S-VOL differed from the one of P-VOL.
•
The state of restore journal differed from the state of master journal.
The pair cannot be created because the specified secondary system did not support the external
volume.
8F67
The pair cannot be created because the specified volume was a command device.
8F6D
The pair cannot be created because the P-VOL is used for Fast Snap or Snapshot.
8FEA
The pair cannot be created because the P-VOL is used for Fast Snap or Snapshot.
8FEC
The command cannot be executed because user authentication is not performed.
9100
The information of the consistency group cannot be retrieved, because Continuous Access Journal
was not installed.
B992
The source of command devise has run out. Set to OFF the command device and to ON again
from the LUN Manager.
B9C0
RAID Manager error codes for Cnt Ac-J: SSB1 = B9E1
Description
Error code (SSB2)
The command was rejected because the specified device is a command device.
B901
RAID Manager error codes for Cnt Ac-J: SSB1 = B901, B9E0, B9E1, B9E2,
B9E4, D004
Description
Error code (SSB2)
The command was rejected because the mirror ID is invalid.
B902
The command was rejected because the volume status was SMPL.
B907
The S-VOL hide mode is not supported.
B90A
The command was rejected because the Cnt Ac-J program product is not installed.
B90D
The command was rejected because the mirror ID is invalid.
B909
A status of Cnt Ac-J pair was acquired at the time of unavailable to use the Cnt Ac-J during the
power-on. Retry the operation.
B900
The command was rejected because the Cnt Ac-J configuration was changed. Check the status
of the Cnt Ac-J pair.
B94B
The command was rejected because the path is not set between the systems.
B90E
112
Troubleshooting