beautypg.com

HP XP P9500 Storage User Manual

Page 116

background image

Description

Error code (SSB2)

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Continuous Access Synchronous. Check the License capacity as well as
the related Program product.

EAA3

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Cnt Ac-J. Check the license capacity as well as the related program
product.

EAA5

The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's Continuous Access Synchronous. Check the license capacity as well as the
related program product.

EAA6

In the configuration where three Cnt Ac-J sites are combined, a request of Cnt Ac-J pair resync
(journal resync mode) was received, but since the specified option was wrong, the command
was rejected.

EAAB

The paircreate operation failed because the primary system’s differential management area had
no free space.

EAB6

If no extended shared memory is installed in the primary system, install it and repeat the operation.

If extended shared memory is installed, the number of pairs that can be created in the system is
exceeded.

The paircreate operation failed because no extended shared memory is installed in the primary
system. Install extended shared memory in the primary system and then repeat the operation.

EAB7

The paircreate operation failed because the secondary system’s differential management area
had no free space.

EAB8

If no extended shared memory is installed in the secondary system, install it and repeat the
operation.

If extended shared memory is installed, the number of pairs that can be created in the system is
exceeded.

The paircreate operation failed because no extended shared memory is installed in the secondary
system. Install extended shared memory in the secondary system and then repeat the operation.

EAB9

The command was rejected because the delta resync function was unsupported.

EAD0

The command was rejected because the specified P-VOL or S-VOL is in the process of having the
capacity changed by Thin Provisioning.

EAE5

The Cnt Ac-J pair cannot be deleted because the specified Cnt Ac-J volume is used as the
Continuous Access Synchronous pair and is working in the journal that was registered when the
2DC Cascade was set to Enable in the Edit Journal Volumes dialog box.

EAE7

The command was rejected because the pair was in the state that was unavailable to transit.

EAF6

The Cnt Ac-J pair for the delta resync operation cannot be created because the specified Cnt Ac-J
S-VOL is in either one of the following statuses:

EB24

Cnt Ac-J volume for the delta resync operation.

The status of the Cnt Ac-J pair is other than PAIR.

The Cnt Ac-J pair for delta resync operation cannot be created because the specified Cnt Ac-J
S-VOL is in either one of the following statuses:

EB25

The volume cannot be used as the Cnt Ac-J volume for the delta resync operation.

The status of the Cnt Ac-J pair is the status other than PAIR or SUSPEND.

The command was rejected because the Cont Access Journal 3DC + 4x4 Open MF program
product was not installed in the secondary system.

EB28

The command was rejected because the delta resync settings are configured to the primary and
secondary systems.

EB29

The command was rejected because the specified Cnt Ac-J pair was used in the system that
consists of multiple primary and secondary systems.

EB2F

116

Troubleshooting