Miscellaneous troubleshooting, Delta resync operation, Suspension among journals – HP XP P9500 Storage User Manual
Page 121: Delta resync operation suspension among journals
SVP log file
System generating the
SIM
Description
Severity
Reference code
Byte 23
Byte 22
A failure has been detected in the
secondary system.
SIM Log
Primary
The P-VOL has been suspended.
Serious
4X
DC
The pair has been suspended at the
secondary system.
SIM Log
Primary
The P-VOL has been suspended.
Serious
5X
DC
A pair has been released at the
secondary system.
SIM Log
Primary
The S-VOL has been suspended.
Serious
6X
DC
Path recovery is impossible.
SIM Log
Secondary
The S-VOL has been suspended.
Serious
7X
DC
A failure has been detected in the
secondary system.
Primary
Yes, repeatedly.
A delta resync P-VOL has been
suspended.
Serious
9X
DC
A failure has been detected in the primary
system.
SIM Log
Primary
A volume used in a P-VOL that is
configured in a multiple primary and
Serious
AX
DC
secondary system combination has been
suspended.
A failure has been detected in other
primary and secondary systems.
Notes:
If the DKC emulation type is 2105 or 2107, the setting of system option mode 308 determines whether the SIM is reported to
the host, as explained below:
•
When system option mode 308 is set to ON, the SIM is reported to the host.
•
When system option mode 308 is set to OFF, the SIM is not reported to the host. By default, system option mode 308 is set
to OFF.
Miscellaneous troubleshooting
Delta resync operation
If the status of the delta resync pair does not change after you performed delta resync operation,
some of the requirements and prerequisites may not have been fulfilled. In that case, after checking
the status of all pairs including the delta resync pair for clues into the problem, review all prerequisite
material in
“Delta resync configuration ” (page 144)
Suspension among journals
All the journals in a consistency group can be suspended when an error occurs in one of the
journals in the consistency group. This takes place under the following conditions:
•
The communications line between the RAID Manager and all primary systems are normal.
•
The status of the failed journal is PJSE or PJSF.
•
At least one journal in the consistency group is in normal status.
Miscellaneous troubleshooting
121