Raid manager error codes for cnt ac-j: ssb1 = b9fe – HP XP P9500 Storage User Manual
Page 119
Description
Error code (SSB2)
The pair operation command was rejected because the specified S-VOL was not mounted on the
secondary system.
EBA0
The command was rejected because the volume specified for the secondary volume was in either
one of the following status.
EBA7
•
Increasing the capacity by Thin Provisioning.
•
Releasing the page of Thin Provisioning.
•
Initializing the pool of Thin Provisioning.
The command was rejected because the license capacity of the Data Retention in the secondary
system exceeds the setting value. Please check the license capacity setting for Data Retention in
the secondary system.
EBAF
The command was rejected because the specified Cnt Ac-J S-VOL was used by either Business
Copy or Compatible FlashCopy.
EBC6
The command was rejected because the journal restore operation is in progress in the Cnt Ac-J
pair through another mirror ID.
EBCA
•
If the Cnt Ac-J pair with another mirror ID is in Suspending status, re-issue the request when
the pair status is changed to the Suspend status.
•
If the Cnt Ac-J pair with another mirror ID is in the PAIR status, reissue the request after awhile.
The command was rejected because un-updated differential data exists in the specified S-VOL.
EBCE
The Cnt Ac-J Pairresync (journal resync mode that forcibly copies all data) was received because
of the Cnt Ac-J Pairresync (delta resync) failed. The command was rejected because the Cnt Ac-J
pair was not in HOLD status.
EBCF
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Continuous Access Synchronous. Check the license capacity as well as
the related program product.
EBD9
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Cnt Ac-J. Check the license capacity as well as the related program
product.
EBDB
The command was rejected because the processing load of the storage system is heavy. Please
execute the command again after a while.
EBDC
The command was rejected because the specified S-VOL was already used in the Cnt Ac-J pair
for delta resync.
EBE0
The command was rejected because the all S-VOLs of the specified restore journal were not the
another Cnt Ac-J's S-VOLs.
EBE1
The command was rejected because the difference was not ready for the journal resync operation.
EBE2
The update data of Continuous Access Synchronous (master journal of the Cnt Ac-J pair for delta
resync operation) is inconsistent with the update data of the restore journal of the Cnt Ac-J pair.
Perform Cnt Ac-J Pairresync (journal resync mode that forcibly copies all data).
The command was rejected because the journal volume of specified restore journal was blocked.
EBE5
The command was rejected because the At-Time Split function is used combining Cnt Ac-J Z with
BC Z and the split time is restored to the specified restore journal.
EBF2
The command was rejected because the split time of the AT-Time Split function is restored.
EBF3
The command was rejected because the specified restore journal was not registered.
EBFD
RAID Manager error codes for Cnt Ac-J: SSB1 = B9FE
Description
Error code (SSB2)
Journal volumes are not registered in the specified journal.
B902
Troubleshooting with RAID Manager
119