beautypg.com

HP Insight Management Agents User Manual

Page 38

background image

Different Firmware—The other controller indicates a different firmware version.

Different Cache—The other controller indicates a different cache size.

Other Cache Failure—The other controller indicates a cache failure.

No Drives—This controller cannot see any attached drives, but the other controller can.

Other No Drives—This controller can see the attached drives, but the other controller
cannot.

Unsupported Drives—One or more attached drives has been determined to be incapable
of properly supporting redundant controller operation.

Expand in Progress—An expand operation is in progress. Redundant operation not
supported until the expand operation is complete.

Unknown—Indicates that the Storage Agents are unable to determine the redundancy
error for the controller. You may need to upgrade the Storage Agents.

Firmware Version—Lists the firmware version of the array controller. This value can be used
to help identify a particular revision of the controller. For B-series array controllers, this value
will be "N/A" (see "RAID Stack Version").

Product Revision—Displays the revision of the array controller board. This value can be used
to help identify a particular revision of the controller.

Serial Number—Displays the serial number for the array controller. Use this number for
identification purposes.

Partner Controller Serial Number—Displays the serial number for the partner array controller.
Use this number for identification purposes.

Processor Usage—Displays the total percentage of the processor usage, expressed as a number
from 0 to 100 inclusive.

Command Count—Displays the total number of read and write commands processed in this
sample. This value is expressed as read and write commands per second.

Command Latency—Displays the average command latency for this sample in 1/100,000 of
a second units.

ADG Enabler Status—Displays the array controller RAID ADG Enabler Module status. The
module enables advanced controller features such as Advanced Data Guarding. The following
values are valid:

Not Supported—Indicates that the RAID ADG Enabler Module is not supported by this
type of controller.

Not Present—Indicates that the RAID ADG Enabler Module is not present or is not
accessible.

Fully Functional—Indicates that the RAID ADG Enabler Module is functional and accessible.

Bad Signature—Indicates that the RAID ADG Enabler Module has an incorrect signature.

Bad Checksum—Indicates that the RAID ADG Enabler Module checksum failed.

Present-Upgrade Firmware—Indicates that the RAID ADG Enabler Module is installed,
but a firmware upgrade is required to make it fully functional.

Unknown—Indicates that the Storage Agents do not recognize the RAID ADG Enabler
Module. You may need to upgrade the Storage Agents.

38

Agent information