beautypg.com

HP Insight Management Agents User Manual

Page 69

background image

IO Module Type displays the storage system chassis SCSI I/O module type that is installed.
The following values are possible:

2 Port Ultra3 SCSI Module - A 2 Port Ultra3 SCSI I/O Module is installed.

4 Port Shared Storage Module - A 4 Port Shared Storage Module for the Smart Array
Cluster Storage is installed.

4 Port - Upgrade Firmware - A 4-Port Shared Storage Module for the Smart Array Cluster
Storage is installed, but the current controller firmware does not support it. The controller
firmware must be upgraded.

2 Port Ultra320 SCSI Module - A 2 Port Ultra320 SCSI I/O Module is installed.

4 Port Ultra320 SCSI Module - A 4 Port Ultra320 SCSI I/O Module is installed.

1 Port Ultra320 SCSI Module - A 1 Port Ultra320 SCSI I/O Module is installed.

Unknown - The Storage Agents cannot determine the IO module type for this storage
system.

RSO Status displays the status of the Recovery Server Option. Two servers are connected to
the storage system so that when one fails the other server takes control of the storage system.
The following values are possible:

OK - The recovery server option is installed and the other server is working correctly.

Secondary Running - Auto - The recovery server option is installed, but the secondary
(standby) server is running in place of the primary server. The secondary server assumed
control automatically.

Secondary Running - User - The recovery server option is installed, but the secondary
(standby) server is running in place of the primary server. The secondary server assumed
control via manual intervention.

Link Down - The recovery server option is installed, but the communications link to the
secondary (standby) server is down.

No Secondary - The recovery server option is installed, but the communications link to
the secondary (standby) server has never been established.

Disabled - The recovery server option is installed, but it has been disabled by software.
This is done to temporarily prevent the secondary server from taking over when the primary
server is brought down. This is used to perform maintenance and other tasks on the
primary server.

Not Configured - The recovery server option is supported, but is not configured on this
storage system.

Not Supported - The recovery server option is not supported for this storage system.

Daemon Down - OK - The recovery server option is installed, but the RSO operating system
daemon is not running. The last RSO status was OK.

Daemon Down - Link Down - The recovery server option is installed, but the RSO operating
system daemon is not running. The last RSO status was Link Down.

Daemon Down - No Secondary - The recovery server option is installed, but the RSO
operating system daemon is not running. The last RSO status was No Secondary.

Daemon Down - Disabled - The recovery server option is installed, but the RSO operating
system daemon is not running. The last RSO status was Disabled.

Storage agent

69