Xp12000 disk array/xp10000 disk array, Host mode option for a volume larger than 2 tb, Xp1024/xp128 disk array – HP XP Racks User Manual
Page 81: Xp512/xp48 disk array, Thunder 9500v
![background image](/manuals/398532/81/background.png)
XP12000 Disk Array/XP10000 Disk Array
Use the following settings on the external system:
•
The port must be set to the host group for the Windows hosts (host mode 0C: Windows, host
mode 2C: Windows Extension).
•
The port attribute must be set to Target port or RCU target port.
•
If the external USP system uses Open LDEV Guard, set SOM 701 to ON on the local HP XP7
Storage system.
Host mode option for a volume larger than 2 TB
If a volume’s capacity is more than 2 TB, host mode option No. 24 must be enabled before mapping
it as an external volume. For instructions, see the LUN Management User's Guide for the XP12000
Disk Array / XP10000 Disk Array storage system.
XP1024/XP128 Disk Array
Use the following settings on the external system:
•
The port must be set to the host group for the Windows hosts (host mode 0C: Windows, host
mode 2C: Windows Extension).
•
The port attribute must be set to Target port or RCU target port.
XP512/XP48 Disk Array
Use the following settings on the external system:
•
The port’s host mode must be set to PC Server (0C).
•
The port attribute must be set to Target port or RCU target port.
Thunder 9500V
The following versions are recommended. If you use an earlier version, the SATA drive information
may not display correctly.
•
For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later.
•
For Thunder 9580V, Thunder 9585V: version 1658 or later.
The following table shows the system parameters that must be specified for ports on the Thunder
9500V storage system.
Parameter Settings
Parameters
Window Names
Start Attribute
System Startup Settings
Use when the Thunder 9500V is in a one-controller
configuration.
Single Mode
Use when the Thunder 9500V is in a two-controller
configuration.
Dual Active Mode
Be sure to specify that Data Share Mode will be used.
Do not specify this parameter.
Hot Stand-By Mode
Optional
Delay Planned Shutdown
Common 1
Optional
SCSI Fibre Channel Common Options
OPTION 1
Optional
SCSI Fibre Channel Common Options
OPTION 2
Reset of occurred
Operation if the processor failure
occurs
Data Striping
XP12000 Disk Array/XP10000 Disk Array