Xp12000 disk array / xp10000 disk array – HP XP Racks User Manual

Page 72

background image

Unified Storage VM, P9500, and XP24000/XP20000 Disk Array

Description and corrective actions

Path Status

External device setting
changed

LU path settings may have been changed by LUN Manager. Either change the settings back
to the values used when the volume was mapped, or perform the Delete Volume and then
Add Volume operations using External Storage.

The volume’s access attribute may have been changed by Data Retention. If the volume is
protected by the access attribute, release the protection.

Illegal request or

If the volume is a pair volume, it may be protected because of the pair status. If this is the
case, change the pair status or delete the pair.

Response error

The volume’s access attribute may have been changed by Data Retention. If the volume is
protected by the access attribute, release the protection.

Cannot detect port

There is a problem with connection to the external storage system. The possible causes are:

- Fibre cable connection. Make sure the fibre cable is connected correctly.

- Fiber Channel port settings. The setting of the topology may not match between the external
port and the target port. Make sure that the Fibre Channel ports are set properly using LUN
Manager.

- Switch settings. If the external storage system is connected through switches, make sure
that the switch settings are correct.

LUN security may have been enabled by LUN Manager. If so, disable it.

XP12000 Disk Array / XP10000 Disk Array

Description and corrective actions

Path Status

External device setting
changed

LU path settings may have been changed by LUN Manager. Either change the settings back
to the values used when the volume was mapped, or perform the Delete LU and then Add
LU operations using External Storage.

The volume’s access attribute may have been changed by Data Retention. If the volume is
protected by the access attribute, release the protection.

Illegal request or

If the volume is a pair volume, it may be protected because of the pair status. If this is the
case, change the pair status or delete the pair.

Response error

The volume’s access attribute may have been changed by Data Retention. If the volume is
protected by the access attribute, release the protection.

Cannot detect port

There is a problem with connection to the external storage system. The possible causes are:

- Fibre cable connection. Make sure the fibre cable is connected correctly.

- Fiber Channel port settings. The setting of the topology may not match between the external
port and the target port. Make sure that the Fibre Channel ports are set properly using LUN
Manager.

- Switch settings. If the external storage system is connected through switches, make sure
that the switch settings are correct.

LUN security may have been enabled by LUN Manager. If so, disable it.