HP Storage Mirroring Software User Manual
Page 127
![background image](/manuals/398329/127/background.png)
125 of 195
ID
Category
Severity
Event Message
Required Response
5109
Failover
Error
The public NIC on source
machine %1 is not
responding to a ping.
The failover target did
not receive an answer to
its ping of the source
machine. Eventually, a
failover will result.
Investigate possible
errors (down server,
network error, etc.).
5110
Failover
Info.
The %1 script "%2" is still
running.
No action required.
5200
Failback
Info..
Failback completed for %1. No action required.
5201
Failback
Info..
IP address %1 was
removed from target
machine's %2 adapter.
No action required.
5202
Failback
Error
Unable to Failback properly
because IP address %1
was missing a
corresponding SubNet
Mask.
Contact technical
support.
5300
Monitoring
Info.
The following IP address
was added to target's
monitoring list: %1
No action required.
5301
Monitoring
Info.
The following IP address
was removed from target's
monitoring list: %1
No action required.
5302
Monitoring
Info.
Drive share information for
%1 has been updated on
the target machine.
No action required.
5303
Monitoring
Info.
The application monitor
script has started
successfully.
No action required.
5304
Monitoring
Info
The application monitor
script has finished
successfully.
No action required.
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (85 pages)
- Software de HP StoreVirtual VSA (127 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)