HP Storage Mirroring Software User Manual
Page 126

124 of 195
ID
Category
Severity
Event Message
Required Response
5002
Service
Info.
Placeholders were
modified to %1.
No action required.
5100
Failover
Info.
Failover completed for %1.
No action required.
5101
Failover
Info.
IP address %1 with subnet
mask %2 was added to
target machine's %3
adapter.
No action required.
5102
Failover
Warning
%1 has reached a failover
condition. A response from
the user is required before
failover can take place.
User intervention has
been configured. Open
the Failover Control
Center and accept or
decline the failover
prompt.
5103
Failover
Info.
Started adding drive shares
from %1 to %2.
No action required.
5104
Failover
Info.
%1 drive shares were taken
over by %2.
No action required.
5105
Failover
Info.
Attempting to run the %1
script.
No action required.
5106
Failover
Info.
The %1 script ran
successfully.
No action required.
5107
Failover
Error
Error occurred in running
%1 script.
Verify that the script
identified exists with the
proper permissions.
5108
Failover
Error
The source machine %1 is
not responding to a ping.
This occurs when all
monitored IP addresses
on the source machine
stop responding to pings.
Countdown to failover
will begin at the first
occurrence and will
continue until the source
machine responds or
until failover occurs.