Enabled/disabled using the, Enable, Suppress problem incident report – HP NonStop G-Series User Manual
Page 183: Creation, Extend problem incident report suppression time, Set data collection volume

Enable Advanced Storage Configuration
This action changes the system's
Advanced Storage Configuration State
attribute to Enabled. This
state must be enabled before you can configure
in SCF or perform Flexible Disk
Configuration.
Enable/Disable Automatic Data Collection
Use to enable or disable automatic collection of data for failed system resources. The current state for
the system is indicated by the
Automatic Data Collection State
attribute. If enabled, when a hardware
failure occurs, data is saved to the location specified by the
Set Days to Persist for Diagnostic Data
action determines how long the files are retained on the
system before being deleted.
Extend Problem Incident Report Suppression Time
Extends the duration of suppression by a specified amount of time (in minutes). This action fails if
the suppression was not enabled at that time.
Rediscover System
Causes OSM to
and
all components within the system.
Rediscover System and ServerNet Cluster
Causes OSM to
and
all components within the system and the ServerNet cluster.
Set Data Collection Volume
Used to specify a volume in which
data collection will take place. The volume
should be something other than $SYSTEM to avoid the possibility of filling that volume with
collected data.
Diagnostic Data Collection Volume
attribute displays the currently specified volume. How long
the files are retained in this volume before being automatically deleted is determined by the
to Persist for Diagnostic Data
action. This value is displayed by the
attribute.
Set Days to Persist for Diagnostic Data
Determines how many days the collected hardware failure data is retained on the system before being
deleted.
Suppress Problem Incident Report Creation
This action, which can be initiated by a user or guided procedure, suppresses the creation of Problem
Incident Reports for the default time of 40 minutes. The default value can be changed in the
OSMCONF file or extended for an action currently in progress by using the