HP NonStop G-Series User Manual
Page 155
Halt Code
The octal halt code emitted by the processor that halted.
0: No halt has occurred.
%53: System freeze occurred.
%74: Software fault occurred.
.
Backpressure State on Internal X Fabric
Whether persistent backpressure is severe enough to
disrupt traffic on the Internal ServerNet X Fabric.
Fault: Backpressure has caused ServerNet traffic on the
Internal ServerNet X Fabric to become blocked.
OK: Backpressure levels are below the threshold level for
disrupting ServerNet traffic.
Unknown: Cannot be determined.
Backpressure State on Internal Y Fabric
Whether persistent backpressure is severe enough to
disrupt traffic on the Internal ServerNet Y Fabric:
Fault: Backpressure has caused ServerNet traffic on the
Internal ServerNet Y Fabric to become blocked.
OK: Backpressure levels are below the threshold level for
disrupting ServerNet traffic.
Unknown: Cannot be determined.
Hardware Freeze Flag
Whether the processor has been frozen by a hardware
error:
True: A hardware error in this processor caused it to
freeze. (Disregard the Halt Code and Lites Register
values.)
False: This processor has not experienced a freeze caused
by a hardware error.
Unknown: Hardware freeze state could not be read.
Online Boot Millicode Firmware
Online Boot Millicode Firmware Update is not supported for processors in S7000 PMF CRUs or on
systems running G06.11 or earlier. The related attributes and action are not displayed for processors
on which this action is not supported.
Default File Name
The name of the file to be used for the Boot Millicode firmware update.
Running Version
The version of the Boot Millicode currently running on the processor.