Actions, Disable advanced, Storage configuration – HP NonStop G-Series User Manual
Page 182: Collect diagnostic data, Action) is retained on the system
Problem Incident Report Creation State
Indicates whether or not OSM's ability to create Problem
Incident Reports has been suppressed. This suppression is
accomplished by the
Suppress Problem Incident Report
action and is desirable to stop dial-out of known
problems, such as those that may occur during CRU
replacements.
Values: Suppressed, Unsuppressed
Reason for Suppression
Why the creation ability was suppressed, displayed as free
form text.
This attribute is shown only if the Problem Incident Report
Creation State value is Suppressed.
Time of Suppression
The date and time the creation ability was suppressed.
This attribute is shown only if the Problem Incident Report
Creation State value is Suppressed.
Duration of Suppression
How long the suppression will last (in minutes). The
default value is 40 minutes. You can extend he time using
the
Extend Problem Incident Report Suppression Time
action.
This attribute is shown only if the Problem Incident Report
Creation State value is Suppressed.
Actions
Add Node to ServerNet Cluster
Launches a guided procedure that adds the local system to a ServerNet Cluster. This procedure is
also used to configure or display information for Expand-over-ServerNet line handlers.
Collect Diagnostic Data
Initiates manual collection of data for a specified system resource. Upon performing the action, you
are prompted to specify the subsystem resource, along with date and time parameters. Supported
resources include PMF, IOMF, SEB/MSEB, Battery, Fan, Power, Disk, Tape, SNDA, FXSA, and
SWAN.
The volume in which this diagnostic data is collected is specified by the
action.
Disable Advanced Storage Configuration
Advanced Storage Configuration State
attribute. In the disabled state, no
advanced storage configuration changes, such as Flexible Disk Configuration or configuration of
ESS disks, can be made on the system.