HP StorageWorks XP Remote Web Console Software User Manual
Page 36

Table 2 Host Mode Options (continued)
When to select this option
Host mode options
No.
When all the following conditions are satisfied:
Automatic recognition
function of LUN
7
•
The host mode 00 Standard or 09 Solaris is used
•
SUN StorEdge SAN Foundation Software Version 4.2 or better is used
•
You want to automate recognition of increase and decrease of devices when
genuine SUN HBA is connected
When all the following conditions are satisfied:
No display for ghost
LUN
12
•
The host mode 08 HP is used
•
You want to suppress creation of device files for devices to which paths are
not defined.
When you want to be informed by SIM (service information message) that the
number of link failures detected between ports exceeds the threshold
SIM report at link failure
13
1
When all the following conditions are satisfied:
HP TruCluster with XP
Continuous Access
function
14
•
The host mode 07 Tru64 is used
•
You want to use TruCluster to set a cluster to each of P-VOL and S-VOL for
XP Continuous Access or HP XP Continuous Access Journal Software.
When all the following conditions are satisfied:
HACMP
15
•
The host mode 0F AIX is used
•
HACMP 5.1 Version 5.1.0.4 or later, HACMP4.5 Version 4.5.0.13 or later,
or HACMP5.2 or later is used
When Veritas Cluster Server is used.
Veritas Cluster Server
22
When you want to shorten the recovery time on the host side if the data transfer
failed.
REC Command Support
23
1
When all the following conditions are satisfied:
Set/Report Device
Identifier enable
33
•
The host mode 03 HP or 05 OpenVMS
2
is used.
•
You want to enable commands to assign a nickname of the device.
•
You want to set UUID to identify a logical volume from the host
When all the following conditions are satisfied:
UUID Option
34
•
The host mode 05 OpenVMS or 07 Tru64 is used
•
You want to set UUID to identify a logical volume from the host.
In case that you want to control the following ranges per host group when
receiving Target Reset:
Change the nexus
specified in the SCSI
Target Reset
39
•
Range of job resettings
•
Range of UAs (Unit Attentions) defined
When all the following conditions are satisfied:
V-Vol expansion
40
•
The host mode 0C Windows or 2C Windows Extension is used
•
You want to automate recognition of the TP-VOL capacity after increasing
the TP-VOL capacity
When you want to execute commands to recognize the device preferentially.
Prioritized device
recognition command
41
When IBM Z10 Linux is used.
Prevent OHUB PCI retry
42
To make the storage system return a “queue full” response to the host when the
command queue is full.
Queue Full response
43
36
Performing LUN Manager Operations