VC Domain Group configuration replicated to other VC Domains during VC Domain Maintenance

IMPORTANT:

The VC Domain, network, and storage configuration changes performed during VC Domain

Maintenance are automatically replicated to all other VC Domains that belong to the same VC Domain
Group when the VC Domain that maintenance operation is confirmed or discarded.

The following information is replicated to all VC Domains in the VC Domain Group during VC Domain
Maintenance:

Domain settings

Configuration for double density servers (for example, BL2x220c)


Configuration for full-height and half-height single density servers (for example, BL460c, BL480c)

Ethernet settings

MAC Cache Failover:

Enable Fast MAC Cache Failover

MAC Refresh Interval

IGMP (Internet Group Management Protocol) Snooping:

Enable IGMP Snooping


IGMP Idle Timeout Interval

Server VLAN Tagging Support:

Tunnel VLAN Taggings or Map VLAN Taggings


Force server connection setting

Multiple Network Speed Settings:

Preferred Link Connection


Preferred Link Connection Speed

Maximum Link Connection

Maximum Link Connection Speed

Network SNMP settings:

Enable SNMP

Read Community

System Contact

Each SNMP trap defined community and IP address

Fibre Channel SAN fabric settings:

Enable SMI-S


Fibre Channel SNMP settings:

Enable SNMP

Read Community

System Contact

Each SNMP trap Community and IP address

For each Fibre Channel fabric:

Fabric name

For each network uplink:

Name


State

VC Domains