Disabling trap severities – HP Virtual Connect Enterprise Manager Software User Manual

Page 32

background image

Do not configure the VC Domain using the enhanced SNMP configuration. If necessary, disable the
enhanced SNMP configuration by following these steps:

1.

Do not configure more than five SNMP trap destinations.

2.

Verify that all SNMP trap destinations follow these rules:
a.

The Destination Name must be in the following format:

__<0 for

VC-Enet and 1 for VC-FC>

(for example, 192.168.1.1_public_1)

b.

Select the “ipv4” option.

c.

Set the SNMP trap format to “SNMPv1.”

Figure 3-4 Adding or editing a compatible SNMP trap destination

d.

To disable trap severities, from the Add a SNMP Trap Destination page, click Advanced, as
shown in the following figure.

Figure 3-5 Disabling trap severities

e.

Trap categories must equal Other for either VC-Enet traps or VC-FC traps. Do not select both.
From the Add a SNMP Trap Destination page, click Advanced, click More, and then select
either of the following:

On the VC-Enet Traps box, select Other, as shown in the following figure.

On the VC-FC Traps box, select Other.

32

Managing VC Domains