Refreshing configuration information, About refreshing configuration information – HP XP P9000 Command View Advanced Edition Software User Manual

Page 260

background image

2.

Click the Monitoring Setting link.

The Monitoring Setting subwindow appears.

3.

Click the link that has the name of the Device Manager server that is an information source to
which the pair management server belongs.

The

Device-Manager-server-name

subwindow appears.

4.

Click the

icon of the pair management server from which you want the copy pair statuses to

be acquired automatically.

The Edit Interval of Refresh Pair Status -

pair-management-server-name

dialog box appears.

5.

Modify the interval settings, and then apply them.

The settings specified in the

Device-Manager-server-name

subwindow are applied. From

this point, the copy pair statuses are automatically refreshed based on the specified settings.

Related topics

About refreshing copy pair status

, page 253

Refreshing the copy pair status automatically for each information source

, page 258

Calculating the copy pair status refresh interval

, page 136

Refreshing configuration information

This module describes methods for refreshing configuration information:

About refreshing configuration information

, page 260

Refreshing configuration information automatically (using the refresh settings)

, page 264

Refreshing configuration information manually for each information source

, page 265

Refreshing configuration information manually for each storage system

, page 265

About refreshing configuration information

In open systems, configuration information is acquired from the databases of Device Manager servers
registered as information sources and from Device Manager agents. If Device Manager servers
installed at multiple sites are used as information sources, configuration information is acquired using
the Device Manager agents for each of those sites. To view the flow of data when configuration
information is refreshed in open systems, see

Data flow when configuration information is refreshed

in open systems

” on page 262.

In mainframe systems, configuration information is acquired from the instances of HP StorageWorks
P9000 for Business Continuity Manager Software or P9000 mainframe agent registered as information
sources. To view the flow of data when configuration information is refreshed in mainframe systems,
see “

Data flow when configuration information is refreshed in mainframe systems

” on page 263.

In Replication Manager, configuration information can be refreshed manually at any time in a
subwindow, or it can be refreshed automatically. Automatic refreshing of configuration information
can be set up using two types of settings:

Automatic updating in conjunction with storage systems refresh operations

Periodic updating based on a specified refresh interval

Replication Manager allows you to use either one or both of the above settings to automatically refresh
configuration information. In the initial settings of Replication Manager, the automatic update setting
is enabled and the periodic update setting is disabled.