beautypg.com

HP XP Racks User Manual

Page 81

background image

Description

SSB2 code

The pair task was rejected because the volume you specified as the S-VOL for BC pair tasks is not an
S-VOL.

2344

The volume you specified as an BC S-VOL is a Cnt Ac-S P-VOL. The pair task was rejected because
the Cnt Ac-S pair is not in the required status.

2346

For more information about the required status for each pair task, see

“Pair status and supported pair

user tasks” (page 65)

.

The volume you specified as an BC S-VOL was a Cnt Ac-S S-VOL. The pair task was rejected because
the Cnt Ac-S pair is not in the required status.

2347

For more information about the required status for each pair task, see

“Pair status and supported pair

user tasks” (page 65)

.

The pair task was rejected because the volume you specified as the S-VOL is the volume of the Auto
LUN.

234B

The pair task was rejected because the specified P-VOL and the S-VOL for BC pair tasks is not a pair.

2350

The pair task was rejected because the volume you specified as the P-VOL and the volume you specified
as the S-VOL are the same.

2351

The pair was not restored because the specified P-VOL and S-VOLs is online to the host.

2352

The pair was not deleted because the specified P-VOL and S-VOLs are in the process of being Quick
Split.

2353

The pairresync RAID Manager command was rejected because the P-VOL and S-VOLs is in the
process of being Steady Split.

2354

The pair creation was rejected because the volume you specified as the S-VOL is the P-VOL of the pair
you are splitting or the P-VOL of the pair you are reverse resynchronizing.

2357

The pairresync RAID Manager command was rejected because the volume you specified as the
S-VOL is the P-VOL of the splitting pair.

2358

The volume you specified as a P-VOL is a Cnt Ac-S P-VOL. The reverse resynchronization was rejected
because the Cnt Ac-S pair is not suspended (“PSUE” status) or split (“PSUS” status).

235B

The volume you specified as the P-VOL is a Cnt Ac-S S-VOL. The reverse resynchronization was rejected
because the Cnt Ac-S pair is not suspended (“PSUE” status) or split (“PSUS” status).

235C

The volume you specified as an S-VOL was a Cnt Ac-S P-VOL. The reverse resynchronization was
rejected because the Cnt Ac-S pair is not suspended (“PSUE” status) or split (“PSUS” status).

235D

The reverse resynchronization was rejected because the volume you specified as the P-VOL has the
S-VOL Disable attribute assigned by the Data Retention.

236C

The pair task was rejected because the volume you specified as the S-VOL has the S-VOL Disable
attribute assigned by the Data Retention.

236D

The pair task was rejected because the volume you specified as the P-VOL is not mounted.

2370

The pair task was rejected because the volume you specified as the P-VOL is blocked.

2371

The pair task was rejected because the volume you specified as the P-VOL is being formatted or
shredded.

2372

The pair task was rejected because the volume you specified as the P-VOL is a command device.

2373

The pair task was rejected because of one of the following reasons:

2380

The volume you specified as the S-VOL is not mounted.

The MU number is 3 or larger.

The pair task was rejected because the volume you specified as the S-VOL is blocked.

2381

The pair task was rejected because the volume you specified as the S-VOL is being formatted or
shredded.

2382

Locating and interpreting error codes and logs using the RAID Manager

81

This manual is related to the following products: