HP XP Racks User Manual
Page 81
Description
SSB2 code
The pair task was rejected because the volume you specified as the S-VOL for BC pair tasks is not an
S-VOL.
2344
The volume you specified as an BC S-VOL is a Cnt Ac-S P-VOL. The pair task was rejected because
the Cnt Ac-S pair is not in the required status.
2346
For more information about the required status for each pair task, see
“Pair status and supported pair
.
The volume you specified as an BC S-VOL was a Cnt Ac-S S-VOL. The pair task was rejected because
the Cnt Ac-S pair is not in the required status.
2347
For more information about the required status for each pair task, see
“Pair status and supported pair
.
The pair task was rejected because the volume you specified as the S-VOL is the volume of the Auto
LUN.
234B
The pair task was rejected because the specified P-VOL and the S-VOL for BC pair tasks is not a pair.
2350
The pair task was rejected because the volume you specified as the P-VOL and the volume you specified
as the S-VOL are the same.
2351
The pair was not restored because the specified P-VOL and S-VOLs is online to the host.
2352
The pair was not deleted because the specified P-VOL and S-VOLs are in the process of being Quick
Split.
2353
The pairresync RAID Manager command was rejected because the P-VOL and S-VOLs is in the
process of being Steady Split.
2354
The pair creation was rejected because the volume you specified as the S-VOL is the P-VOL of the pair
you are splitting or the P-VOL of the pair you are reverse resynchronizing.
2357
The pairresync RAID Manager command was rejected because the volume you specified as the
S-VOL is the P-VOL of the splitting pair.
2358
The volume you specified as a P-VOL is a Cnt Ac-S P-VOL. The reverse resynchronization was rejected
because the Cnt Ac-S pair is not suspended (“PSUE” status) or split (“PSUS” status).
235B
The volume you specified as the P-VOL is a Cnt Ac-S S-VOL. The reverse resynchronization was rejected
because the Cnt Ac-S pair is not suspended (“PSUE” status) or split (“PSUS” status).
235C
The volume you specified as an S-VOL was a Cnt Ac-S P-VOL. The reverse resynchronization was
rejected because the Cnt Ac-S pair is not suspended (“PSUE” status) or split (“PSUS” status).
235D
The reverse resynchronization was rejected because the volume you specified as the P-VOL has the
S-VOL Disable attribute assigned by the Data Retention.
236C
The pair task was rejected because the volume you specified as the S-VOL has the S-VOL Disable
attribute assigned by the Data Retention.
236D
The pair task was rejected because the volume you specified as the P-VOL is not mounted.
2370
The pair task was rejected because the volume you specified as the P-VOL is blocked.
2371
The pair task was rejected because the volume you specified as the P-VOL is being formatted or
shredded.
2372
The pair task was rejected because the volume you specified as the P-VOL is a command device.
2373
The pair task was rejected because of one of the following reasons:
2380
•
The volume you specified as the S-VOL is not mounted.
•
The MU number is 3 or larger.
The pair task was rejected because the volume you specified as the S-VOL is blocked.
2381
The pair task was rejected because the volume you specified as the S-VOL is being formatted or
shredded.
2382
Locating and interpreting error codes and logs using the RAID Manager
81