Selected Pairs table
The following table shows the items in this table in the Resync Pairs window of the Resync Pairs
wizard.
Description
Item
The P-VOL information.
Primary Volume
Values:
•
LDEV ID: The P-VOL’s LDEV identifier
•
LDEV Name: The P-VOL’s LDEV name
•
Emulation Type: The P-VOL’s emulation type
•
Capacity: The P-VOL’s volume capacity
•
CLPR: The P-VOL’s CLPR number
The pair type.
Copy Type
Values:
•
BC-L1: BC/SS L1
•
BC-L2: BC/SS L2
•
BC Z: BC Z
•
FS: FS
The status for the pair.
Status
For more information about pair status, see
“The RWC pair status names and
The S-VOL information.
Secondary Volume
Values:
•
LDEV ID: The S-VOL’s LDEV identifier
•
LDEV Name: The S-VOL’s LDEV name
•
Emulation Type: The S-VOL’s emulation type
•
Capacity: The S-VOL’s volume capacity
•
CLPR: The S-VOL’s CLPR number
The mirror unit number.
Mirror Unit
The type of resynchronization.
Resync Type
Values:
•
Normal Copy (Primary > Secondary)
•
Reverse Copy (Secondary > Primary)
•
Quick Resync (Primary > Secondary)
•
Quick Restore (Secondary > Primary)
Default: Normal Copy (Primary > Secondary)
For more information about the methods you can use to resynchronize pairs,
see
“Types of pair resynchronization” (page 52)
BC and BC Z only.
Copy Pace
The system option that determines the rate at which you want the XP7 storage
system to copy data.
Values:
•
Slower: Improved host server I/O performance but slower processing speed.
•
Medium: Average processing speed and host server I/O performance.
•
Faster: Faster processing speed but slower host server I/O performance.
Resync Pairs wizard
119