HP XP Racks User Manual
Page 79

Description
SSB2 code
The pair creation was rejected because one of the following applied to the volume specified as the
P-VOL.
20F6
•
The volume was undergoing online data migration.
•
The volume was already used as the S-VOL of an SI pair whose P-VOL was undergoing online data
migration.
The pair operation was rejected because one of the following applied to the volume specified as the
P-VOL.
20F7
•
The volume was undergoing online data migration.
•
The volume was already used as the S-VOL of an SI pair whose P-VOL was undergoing online data
migration.
The pair task was rejected for the volume specified as the S-VOL because the volume is undergoing
online data migration.
20F8
The command was rejected because the volume specified as the P-VOL is undergoing online data
migration and the command is for creating a third pair.
20FC
The pair task was rejected because the volume you specified as the P-VOL is a Compatible FlashCopy
T-VOL.
22F6
The pair task was rejected because the volume you specified as the S-VOL is a Compatible FlashCopy
S-VOL or T-VOL.
22F7
The pair was not restored because the volume you specified as the S-VOL is a Compatible FlashCopy
S-VOL or T-VOL.
22F9
The pair task was rejected because there is not a sufficient amount of installed shared memory or BC
is not installed.
2301
The pair task was rejected because the LBA size of the specified P-VOL is not the same as the size of
the specified S-VOL.
2306
The pair was not created because the number of pairs exceeded the maximum number of pairs.
2309
The pair was not created because the volume you specified as the S-VOL is the P-VOL of the BC pair
that has an MU number of 0.
230A
The pair task was rejected because the pair is being suspended or deleted.
230B
One of the following occurred:
2310
•
Pair creation was rejected because the specified CG number had already been used for an L1
pair.
•
Pair creation was rejected because the specified CG number had already been used for an L2
pair.
•
Pair creation was rejected because the volume you specified as the P-VOL is the S-VOL of the pair
which is in the process of being Quick Split.
•
The Quick Restore was rejected because the VLL setting of the P-VOL is different from that of the
S-VOL.
•
The pair task was rejected because the specified P-VOL and S-VOLs were a Compatible FlashCopy
pair.
•
The reverse resynchronization was rejected because the pair of the specified P-VOL and S-VOLs
is suspended (“PSUE” status).
•
The reverse resynchronization was rejected because the specified P-VOL and the S-VOL is the L2
pair.
•
The CG pair-split was rejected because some of the pairs in the CG were being resynchronized,
split, or were already suspended.
•
The pair task was rejected because the pair status of the P-VOL, the S-VOL, or both showed that
the pair could not receive the issued command.
The pair task was rejected because the volume you specified as the S-VOL is online to the host.
2312
Locating and interpreting error codes and logs using the RAID Manager
79