HP XP Racks User Manual
Page 77

Description
SSB2 code
The pair task was rejected because the current microcode version does not support the specified P-VOL
capacity.
2047
The pair task was rejected because the current microcode version does not support the specified S-VOL
capacity.
2048
The pair was not created because the specified MU number is in use.
205B
The volume you specified as an BC P-VOL was a volume of a Cnt Ac-J pair. The pair task was rejected
because the status of the Cnt Ac-J pair is not in the required status.
2060
For more information about the required status for each pair task, see
“Pair status and supported pair
.
The volume you specified as an BC S-VOL was a volume of a Cnt Ac-J pair. The pair task was rejected
because the status of the Cnt Ac-J pair is not in the required status.
2061
For more information about the required status for each pair task, see
“Pair status and supported pair
.
Volumes of the specified pair are shared by Cnt Ac-S and Cnt Ac-J. The reverse resynchronization
was rejected because the Cnt Ac-S or Cnt Ac-J pair is not split (“PSUS” status).
2067
The pair task was rejected because of one of the following reasons:
2072
•
The P-VOL is also an FS pool volume.
•
The P-VOL is also an FS S-VOL.
•
The P-VOL is also an FS P-VOL, and one of the following conditions is also true:
- While restoring the FS pair, you created, split, or resynchronized the BC pair.
- You performed the BC Quick Restore.
- You defined a CG for BC.
- After you specify the MU number an FS pair is using, you created, split, or resynchronized the
BC pair.
The pair task was rejected because of one of the following reasons:
2073
•
The S-VOL is also an FS pool volume.
•
The S-VOL is also an FS S-VOL or an FS V-VOL.
•
The S-VOL is also an FS P-VOL, and you created an BC pair or performed an BC Quick Restore
operation.
•
The S-VOL is also an FS P-VOL, and you split, resynchronized, or suspended an BC pair while
restoring the FS pair.
Because the specified P-VOL was also a Cnt Ac-J P-VOL for delta resync, one of the following errors
occurred:
2078
•
The Reverse Copy was rejected because the Cnt Ac-J pair status is not “PSUS”.
•
The Quick Restore was rejected.
The pair task was rejected because the specified S-VOL was also a Cnt Ac-J P-VOL for delta resync.
2079
The pair task was rejected because the initialization process is being performed.
2086
The Quick Restore was rejected because you are formatting the volume you specified as a P-VOL
using Quick Format.
2089
For more information about formatting volumes using Quick Format, see the HP XP7 Provisioning for
Open Systems User Guide.
The Quick Restore was rejected because you are formatting the volume you specified as an S-VOL
using Quick Format.
208A
For more information about formatting volumes using Quick Format, see the HP XP7 Provisioning for
Open Systems User Guide.
Locating and interpreting error codes and logs using the RAID Manager