Snmp configuration parameters – HP Switch SFP Modules User Manual
Page 50

Managing H3C LSW1FC4P0 Interface Card
Configuring an H3C LSW1FC4P0 Interface Card
40
59273-00 C
SNMP Configuration
The SNMP configuration defines how authentication
traps are managed.
describes the SNMP configuration parameters. The
illegal characters for the user-defined fields are the pound sign (#), semi-colon (;),
and comma (,).
Table 2-9. SNMP Configuration Parameters
Parameter
Description
SNMP Enabled
Enables or disables SNMP communication with other H3C
LSW1FC4P0 Interface Cards in the fabric. If disabled, the user can-
not use an SNMP application at a workstation to talk to the H3C
LSW1FC4P0 Interface Card that has this setting disabled.
Contact
Specifies the name (up to 64 characters) of the person who is to be
contacted to respond to trap events. The default is “undefined”.
Read Commu-
nity
Read community password (up to 32 characters) that authorizes an
SNMP agent to read information from the H3C LSW1FC4P0 Inter-
face Card. This is a write-only field. The value on the H3C
LSW1FC4P0 Interface Card and the SNMP management server
must be the same. The default is “public”.
SNMP Proxy
If enabled, you can use SNMP to monitor and configure any H3C
LSW1FC4P0 Interface Card in the fabric.
Location
Specifies the name (up to 64 characters) for the H3C LSW1FC4P0
Interface Card location. The default is “undefined”.
Authentication
Trap
Enables or disables the reporting of SNMP authentication failures. If
enabled, a notification trap is sent when incorrect community string
values are used. The default value is "False".
Write Commu-
nity
Write community password (up to 32 characters) that authorizes an
SNMP client to write information to the H3C LSW1FC4P0 Interface
Card. This is a write-only field. The value on the H3C LSW1FC4P0
Interface Card and the SNMP management server must be the
same. The default is “private”.