HP Switch SFP Modules User Manual
Page 25

Managing H3C LSW1FC4P0 Interface Card
Displaying Interface Card Information
59273-00 C
15
Temperature Failure Port
Shutdown
Non-configurable (always enabled for this H3C
LSW1FC4P0 Interface Card). All ports are downed when
the H3C LSW1FC4P0 Interface Card temperature
exceeds the Failure Temperature.
ASIC Temperature
Temperature of the ASIC
ASIC Warning Tempera-
ture
Non-configurable temperature threshold (102° Celsius)
above which a warning condition alarm is generated.
ASIC Failure Temperature
Non-configurable temperature threshold (105° Celsius)
above which a failure condition alarm is generated.
Board Temperature
Temperature of the Board
Board Warning Tempera-
ture
Non-configurable temperature threshold (75° Celsius)
above which a warning condition alarm is generated.
Board Failure Temperature
Non-configurable temperature threshold (81° Celsius)
above which a failure condition alarm is generated.
POST Status
Status from the most recent Power On Self Test
POST Fault Code
Fault code from the most recent Power On Self Test
Test Status
The current diagnostic test status of the H3C
LSW1FC4P0 Interface Card.
Test Fault Code
The code value for the last recorded diagnostic test status
recorded on the H3C LSW1FC4P0 Interface Card.
Network Group
IPv4 Enabled
Internet Protocol version 4 Enabled status
IPv4 Address
Mask that determines the IP address subnet
IPv4 Subnet Mask
Mask that determines the IP address subnet
IPv4 Gateway
IPV4 gateway address
IPv6 Enabled
Internet Protocol version 6 Enabled status
IPv6 Address
Mask that determines the IP address subnet
IPv6 Gateway
IPV6 gateway address
CPU0 MAC Address
N/A - does not apply to this switch
CPU1 MAC Address
N/A - does not apply to this switch
SNMP Enabled
SNMP enabled or disabled
Table 2-3. Switch Data Window Entries (Continued)
Entry
Description