Server profile network configuration was lost – HP Virtual Connect Enterprise Manager Software User Manual

Page 98

background image

Error during Edit server profile [Profile Name]. Details: This action could

not be performed because the server is powered on. Power down the server

associated with the Server Bay and retry the operation.

VCEM server profile editor does not prevent profile edit operations in case the target server is powered off.
However, the VCEM server profile edit job might fail depending on what profile changes each VC Domain
firmware version allows in case the target server is powered on.

Server profile network connections that use multiple networks are not working

If a VC Domain has a network connection from a server profile configured to use multiple networks, and the
VC Domain is not working as expected, the network that was selected to the untagged network might not
be correctly reflected in the VC Domain.

To resolve this issue:

1.

Power down the server blade.

2.

Select the server profile that is presenting the problems, and then click Edit.

3.

Verify that the multiple networks configuration for that server profile is correct. Verify that the Untagged
network is correctly selected.

4.

Click OK.

5.

Power on the server blade.

6.

From VC Domain Maintenance, upgrade the VC Domain Firmware to the latest version.

Server profile network configuration was lost

If a VC Domain has server profiles configured to use multiple networks and there is a network selected to
be untagged, the network configurations can be lost.

To resolve this issue:

1.

From VC Domain Maintenance, upgrade the VC Domain firmware to the latest version.

2.

Edit the server profile, and then set the multiple networks configuration.

VC Domain status is "Mismatch Configuration" after cancel VC Domain Maintenance
operation fails

This situation occurs when the server profiles from a VC Domain managed by VCEM have changed and do
not match the existing server profiles in the VCEM database. For example, restoring an old VC Domain
backup that has a different server profile form the current VC Domain in the VCEM database.

In such cases, VCEM changes the VC Domain status to "Mismatch Configuration," and the VC Domain
Group to, "Configuration in sync." To continue managing this VC Domain with VCEM, click VC Domain
Maintenance

to resynchronize the VC Domain configuration and server profiles.

Server profile job completed with success but changes have not occurred

If a VC Domain is managed by VCEM, and Onboard Administrator is brought out of Virtual Connect Mode,
the following error message appears the next time you log in to Virtual Connect Manager:

The HP virtual connect has lost its login credentials for the HP Onboard

Administrator (OA). OA may have been replaced or reset to factory defaults.

To ensure proper operation, these credentials must be reestablished.

When the Onboard Administrator credentials are provided, an error message appears stating that the
credentials are not valid. This situation can occur when:

Onboard Administrator is replaced or reset to factory default settings.

The clear vcmmode command was executed in the Onboard Administrator command line interface.

The VC Ethernet modules were temporarily replaced by another BladeSystem c-Class interconnect
module.

98