beautypg.com

13 troubleshooting vcem, Troubleshooting, A job appears with failed status – HP Virtual Connect Enterprise Manager Software User Manual

Page 87

background image

13 Troubleshooting VCEM

Troubleshooting

IMPORTANT:

VCEM 6.0 supports the Microsoft Internet Explorer 8 (IE8) browser, but the underlying Virtual

Connect Manager does not currently provide the same level of support. Using IE8 to perform VCEM Domain
Maintenance tasks that access Virtual Connect Manager might result in failed or incomplete operations. HP
recommends Microsoft Internet Explorer 7 (IE7) or Firefox 3.0 or 3.5 as the preferred browsers for use with
VCEM. For a list of browsers supported by Virtual Connect Manager, see the

HP Virtual Connect for c-Class

BladeSystem User Guide.

When you are upgrading to a new and different CMS, or are moving to a 64-bit CMS, then you might need
to migrate your data by using the HP SIM data migration tool. If you are upgrading to a new version of
VCEM on the same CMS, data migration with the HP SIM data migration tool is not necessary. For more
information, see the

Data migration of an existing MS Windows CMS to a new Insight Software 6.0 system

white paper on the HP SIM Information Library at

http://h18013.www1.hp.com/products/servers/

management/hpsim/infolibrary.html?jumpid=reg_R1002_USEN#b3

.

Unauthorized error when trying to access the VCEM home page

VCEM requires the CMS to be correctly registered in the DNS. Make sure HP SIM can correctly discover
the CMS. You might experience an unauthorized error page when trying to access the VCEM home page
if the CMS is incorrectly registered in the DNS.

To correct this issue, register the CMS in DNS or add the CMS hostname to the Windows hosts file.

A job appears with Failed status

A job might fail for several reasons. For more information about the reason of job failure and how to correct
the issue, see the job details:

1.

From the VCEM home page, click the Jobs tab.

2.

Locate the job, either by its ID or its name.

3.

For detailed information about the job and how you can resolve the issue, click the task name of this
job.

4.

(Optional) Job details might appear to be truncated when the appended exceeds 256 characters. If
this occurs, to view the full job details, go to HP SIM left navigation panel

EventsSharedVCEM

Events

.

Enclosure has two Onboard Administrators, and one fails

If an enclosure has two Onboard Administrators with redundancy and one fails, then the redundant Onboard
Administrator might take several minutes to take over. Before performing any operations to the VC Domain,
wait until the Onboard Administrator has failed over. Perform an HP SIM discovery to rediscover the new
Onboard Administrator IP address. If it is not rediscovered then see the

HP BladeSystem c-Class Onboard

Administrator User Guide.

VCEM is prompting for Onboard Administrator credentials on a configured VC
Domain

VCEM might prompt for Onboard Administrator credentials on a VC Domain that has already been configured
where the Onboard Administrator has been imported and discovered. This issue occurs when a backup VC
is discovered or if a failover of a VC Module occurred in a redundancy environment. To correct this issue,
perform a rediscovery on the Onboard Administrator IP address associated with the VC Module.

Virtual Connect Manager does not accept Onboard Administrator credentials

If a VC Domain is being managed by VCEM, and the Onboard Administrator is brought out of Virtual
Connect Mode, the following error message appears the next time you log into Virtual Connect Manager:

Troubleshooting