Description

Error code

(SSB2)

The P-VOL is not accessible.

C35C

There are fewer paths than the required minimum following a path failure or because an invalid path was
specified.

C370

The process that is performed after the copying process of Auto LUN in the S-VOL is in progress. Retry the
operation several minutes later.

C371

The process that is performed after the copying process of Auto LUN in the P-VOL is in progress. Retry the
operation several minutes later.

C372

A request for a Paircreate operation was rejected because the specified S-VOL is a Business Copy Reserved
volume.

C373

A request for a Paircreate operation was rejected because the specified P-VOL is a Business Copy Reserved
volume.

C374

There are fewer paths than the required minimum following a path failure or because an invalid path was
specified.

C379

An internal error occurred.

C37A

The S-VOL is not available.

C37B

The S-VOL cache is unavailable.

C37E

The S-VOL DFW is disabled.

C37F

The primary system cache is in transition to blockage on one side.

C380

The primary system cache is in the process of being restored.

C381

The primary system cache is either in transition to blockage on one side or in the process of being restored
on one side.

C382

The pair cannot be created because the emulation type is not available for the specified volume.

C388

The secondary system is already used by Cnt Ac-S.

C38B

The S-VOL is not available.

C38D

The S-VOL is not supported by Cnt Ac-S.

C38E

The S-VOL status is not PSUS or PSUE.

C390

The S-VOL cannot be copied to because it is in the wrong pair status.

C391

The volume cannot be used as an S-VOL because it is in reserve status, is already being used by Cnt Ac-S,
or is being used by Cnt Ac-J.

C392

The S-VOL includes PIN data.

C393

The S-VOL cannot be used due to LDEV blockage, collection access, or other reasons.

C395

The pair cannot be created because the emulation type is not available for the specified volume.

C398

An internal error occurred.

C39B

The pair cannot be created because the capacity of the P-VOL exceeded the maximum volume capacity
allowed to create a Cnt Ac-S pair.

C39E

The pair cannot be created because the capacity of the S-VOL exceeded the maximum volume capacity
allowed to create a Cnt Ac-S pair.

C39F

The P-VOL is a device not supported by Cnt Ac-S.

C3A0

The SSID or CU number of the secondary system is invalid.

C3A6

The device type combination between the P-VOL and S-VOL is invalid.

C3A8