Error code
(SSB2)
The command was rejected because the pair resync was operated on a volume whose status is other than
PSUS, PSUE, or PDUB.
C239
The command was rejected because an internal logical error has occurred.
C23A
The command was rejected because the volume status is SMPL.
C23B
The command was rejected because the volume status is other than PAIR or COPY.
C23C
The command was rejected because the command for Cnt Ac-S asynchronous was issued to the Cnt Ac-S
asynchronous volume.
C23D
The pair cannot be created because the command was issued to the command device.
C267
The command was rejected because the specified consistency group number is invalid.
C271
The command was rejected because the takeover command was issued to a volume whose status is not
SSWS.
C28B
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C28C
There is no volume to which the takeover command can run.
C28D
The command was rejected because an internal logical error has occurred.
C28E
The command was rejected because the specified volume is used as an S-VOL.
C297
The pair cannot be created because the capacity that is used by software products other than Cnt Ac-S
exceeds license capacity.
C2A0
The command was rejected because an internal logical error has occurred.
C2A1
The pair cannot be created because the used capacity exceeds the license capacity.
C2A3
The command was rejected because THP V-VOL capacity is changing.
C2B3
The command was rejected because an internal logical error has occurred.
C2B4
The pair cannot be created because the Cnt Ac-S P-VOL is being initialized by Business Copy.
C2B5
The command was rejected because the releasing pages in THP V-VOL is in progress.
C2B6
The Cnt Ac-S pair associated with a Cnt Ac-J pair cannot be created because the Cont Access Journal 3DC
& 4x4 Open MF program product is not installed on the primary system.
C300
The Cnt Ac-S pair associated with a Cnt Ac-J pair cannot be created because the Cont Access Journal 3DC
& 4x4 Open MF program product is not installed on the secondary system.
C301
The pair cannot be created because the S-VOL is a THP V-VOL.
C304
The pair cannot be created because the capacity that is used by Cnt Ac-S in the secondary system exceeds
license capacity. Check license capacity, including for related software products.
C305
The volume in the secondary system or another volume that belongs to the same group is changing to Simplex
or Suspend status. Retry the operation after several minutes.
C30D
The P-VOL is not in SMPL status.
C312
The P-VOL is not in PSUS or PSUE status.
C313
The P-VOL is not in SMPL status.
C314
The P-VOL includes PIN data.
C315
The P-VOL is in the process of drive copy for failure assistance.
C316
The P-VOL is in the process of drive copy for an SVP request.
C317
The P-VOL is terminating the copy task.
C318
Troubleshooting using RAID Manager