Actions – HP NonStop G-Series User Manual
Page 97

Vendor ID
The supplier of the component.
Path B
Fibre Channel
Controller
Identifies the FCSA FSAC connected to the disk drive enclosure through Port
B.
Example: FCSA FSAC (111.2.1.1)
Configured
Controller Location
The location of FCSA connected to the disk drive through Port B.
Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1
Path A
Fibre Channel
Controller
Identifies the FCSA FSAC connected to the disk drive enclosure through Port
A.
Example: FCSA FSAC (111.2.1.1)
Configured
Controller Location
The location of FCSA connected to the disk drive through Port A.
Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1
Actions
Blink All LEDs Off
Turns off the blinking of the fault LEDs on the disk drive enclosure, disks, FC-AL I/O module,
power supplies, and fans.
Blink All LEDs On
Causes the fault LEDs on the disk drive enclosure, disks, FC-AL I/O module, power supplies, and
fans to blink.
Disable All Drive Bypass
Opens up the specified port or ports (A and/or B) on all disk drives in the enclosure for use.
Enable All Drive Bypass
Shuts down the specified port or ports (A and/or B) on all disk drives in the enclosure.
Set Locator
Allows you to assign identification text, up to 64 characters, that is displayed by the Disk Drive
Enclosure Locator attribute.
Set Rack Name and Offset