The system has two internal ServerNet fabric objects, the Internal ServerNet X Fabric and the
Internal ServerNet Y Fabric. These objects can be expanded in the tree pane to see the Processor
Switch components assocuated with each fabric.
Location in OSM Tree: Under System
Example: Internal ServerNet Y Fabric
Attributes
Internal ServerNet Y Fabric
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.
Actions
Group Connectivity ServerNet Path Test
You can perform this action on either the Internal ServerNet X Fabric or the Internal ServerNet Y
Fabric. The action tests the links between SPs and ServerNet Switch Board maintenance entities
(MEs) that provide ServerNet communication between groups on the system.
Start ServerNet
Starts all ServerNet traffic through all or specified processors on the fabric.
Stop ServerNet
Stops all ServerNet traffic through all or specified processors on the fabric.
IOAM (I/O Adapter Module)
A modular I/O adapter module. There are two IOAMs in each
Each IOAM contains:
●