beautypg.com

Switch fan, Attributes – HP NonStop G-Series User Manual

Page 241

background image

SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y }, FABRIC { X| Y }

Soft Reset

Used following a Firmware Update action on the switch for the changes to take effect.

SCF Equivalent: SCF RESET SWITCH $ZZSMN, NEAREST { X | Y }, SOFT

Switch Fan

Attributes

Actions

A component that circulates air into the enclosure to help maintain optimal temperature.

Location in OSM tree: External ServerNet Fabric > Switch Group > Switch Module > Switch
Fan

Example: Fan (1020.1.16)

Attributes

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Presence

Whether the fan is installed and responding.

Values: Present, Absent, Unknown

LED State

The state of the fault LED on the fan.

Values: On, Off, Blinking

Logical

Enabled State

The initial state of the component at the time of discovery.

Enabled: The component is operational.

Disabled: The component is present but not operational, possibly because the
Disable action was performed.

Device State

Indication of whether the fan has a fault.

Values: OK, Fault